// CODE SNIPPET
R309.2.2 Horizontal Separations
Go To Full Code Chapter
Where horizontal construction is used to separate the garage from the living space or its attic, such construction shall be protected with one layer of 5/8-inch thick, type X, gypsum board, installed in accordance with the requirements of Section R805.1. Openings in horizontal separations shall not be permitted except where the residence is otherwise protected by vertical separations. Where the horizontal separation is a floor-ceiling assembly, the structure supporting the separation shall also be protected by not less than 5/8-inch (15.87 mm) type X gypsum board or equivalent.
Related Code Sections
419.3 Special Detailed Requirements Based on Use and Occupancy, Horizontal Separation
Floor/ceiling assemblies separating dwelling units in the same buildings and floor/ceiling assemblies separating sleeping units in the same building ...
420.3 Special Detailed Requirements Based on Use and Occupancy, Horizontal Separation
assemblies separating dwelling or sleeping units from other occupancies contiguous to them in the same building shall be constructed as horizontal assemblies ...
420.3 Special Detailed Requirements Based on Occupancy and Use, Horizontal Separation
assemblies separating dwelling or sleeping units from other occupancies contiguous to them in the same building shall be constructed as horizontal assemblies ...
R309.2.2 Building Planning, Horizontal Separations
Where horizontal construction is used to separate the garage from the living space or its attic, such construction shall be protected with one layer ...
510.2 General Building Heights and Areas, Horizontal Building Separation Allowance
, limitation of number of stories and type of construction where all of the following conditions are met:
The buildings are separated with a horizontal ...