• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1305.9.3 Horizontal Offsets

NYC Mechanical Code 2008 > 13 Fuel-Oil Piping and Storage > 1305 Fuel-Oil System Installation > 1305.9 Supplemental Requirements for Piping From Transfer Pumps to Equipment or Storage Tanks Above Lowest Floor > 1305.9.3 Horizontal Offsets
JUMP TO FULL CODE CHAPTER
Where it is necessary to make horizontal offsets in the supply piping and pipe shafts, such piping shall be enclosed in a sleeve of other piping of at least No. 10 standard Gage steel, two sizes larger than the supply piping and arranged to drain into the shaft. Horizontal piping offsets shall be further enclosed in construction having a 2-hour fire-resistance rating except that no such enclosure or pipe sleeve shall be required within the room containing the pump, tank, or equipment where such room is itself enclosed with construction and materials having at least a 2-hour fire-resistance rating.

Related Code Sections


1305.9.3 Fuel-Oil Piping and Storage, Horizontal Offsets
Where it is necessary to make horizontal offsets in the supply and overflow/return piping and pipe shafts, including the lowest level, such piping ...
NYC Mechanical Code 2014 > 13 Fuel-Oil Piping and Storage > 1305 Fuel-Oil System Installation > 1305.9 Supplemental Requirements for Piping From Transfer Pumps to Equipment or Storage Tanks Above Lowest Floor > 1305.9.3 Horizontal Offsets
1305.9.3 Fuel-Oil Piping and Storage, Horizontal Offsets
Where it is necessary to make horizontal offsets in the supply piping and pipe shafts, such piping shall be enclosed in a sleeve of other piping ...
NYC Mechanical Code 2008 > 13 Fuel-Oil Piping and Storage > 1305 Fuel-Oil System Installation > 1305.9 Supplemental Requirements for Piping From Transfer Pumps to Equipment or Storage Tanks Above Lowest Floor > 1305.9.3 Horizontal Offsets
915.1 Vents, Vent for Horizontal Offset of Drainage Stack
Horizontal offsets of drainage stacks shall be vented where five or more branch intervals are located above the offset. The offset shall be vented ...
NYC Plumbing Code 2014 > 9 Vents > 915 Vents for Stack Offsets > 915.1 Vent for Horizontal Offset of Drainage Stack
915.1 Vents, Vent for Horizontal Offset of Drainage Stack
Horizontal offsets of drainage stacks shall be vented where five or more branch intervals are located above the offset. The offset shall be vented ...
NYC Plumbing Code 2008 > 9 Vents > 915 Vents for Stack Offsets > 915.1 Vent for Horizontal Offset of Drainage Stack
710.1.1 Sanitary Drainage, Horizontal Stack Offsets
Horizontal stack offsets shall be sized as required for building drains in accordance with Table 710.1(1), except as required by Section 711.4 ...
NYC Plumbing Code 2014 > 7 Sanitary Drainage > 710 Drainage System Sizing > 710.1 Maximum Fixture Unit Load > 710.1.1 Horizontal Stack Offsets
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE