3308.7.4 Horizontal Gap
JUMP TO FULL CODE CHAPTER
The guardrail system shall be installed so that there exists no horizontal gap larger than 1 inch (25 mm) as measured along the perimeter of the building from the edge of the guardrail system to any building column or façade.
Related Code Sections
3308.7.4 Safeguards During Construction or Demolition, Horizontal Gap
The guardrail system shall be installed so that there exists no horizontal gap larger than 1 inch (25 mm) as measured along the perimeter ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3308 Protection of Unenclosed Perimeters > 3308.7 Guardrail System > 3308.7.4 Horizontal Gap