Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

712.1.13.1 Horizontal Fire Door Assemblies

Building Code 2018 of Illinois > 7 Fire and Smoke Protection Features > 712 Vertical Openings > 712.1 General > 712.1.13 Openings > 712.1.13.1 Horizontal Fire Door Assemblies
JUMP TO FULL CODE CHAPTER
Horizontal fire door assemblies used to protect openings in fire-resistance-rated horizontal assemblies shall be tested in accordance with NFPA 288, and shall achieve a fire-resistance rating not less than the assembly being penetrated. Horizontal fire door assemblies shall be labeled by an approved agency. The label shall be permanently affixed and shall specify the manufacturer, the test standard and the fire-resistance rating.

Related Code Sections


712.1.13.1 Fire and Smoke Protection Features, Horizontal Fire Door Assemblies
Horizontal fire door assemblies used to protect openings in fire-resistance-rated horizontal assemblies shall be tested in accordance with NFPA ...
Building Code 2021 of Illinois > 7 Fire and Smoke Protection Features > 712 Vertical Openings > 712.1 General > 712.1.13 Openings > 712.1.13.1 Horizontal Fire Door Assemblies
712.1.13.1 Fire and Smoke Protection Features, Horizontal Fire Door Assemblies
Horizontal fire door assemblies used to protect openings in fire-resistance-rated horizontal assemblies shall be tested in accordance with NFPA ...
Building Code 2018 of Illinois > 7 Fire and Smoke Protection Features > 712 Vertical Openings > 712.1 General > 712.1.13 Openings > 712.1.13.1 Horizontal Fire Door Assemblies
716.2.5.1.2.1 Fire and Smoke Protection Features, Horizontal Exits
Fire-protection-rated glazing shall be permitted as vision panels in self-closing swinging fire door assemblies serving as horizontal exits ...
Building Code 2021 of Illinois > 7 Fire and Smoke Protection Features > 716 Opening Protectives > 716.2 Fire Door Assemblies > 716.2.5 Glazing in Fire Door Assemblies > 716.2.5.1 Size Limitations > 716.2.5.1.2 Fire-Protection-Rated Glazing in Door Assemblies in Fire Walls and Fire Barriers Rated Greater Than 1 Hour > 716.2.5.1.2.1 Horizontal Exits
716.2.5.1.2.1 Fire and Smoke Protection Features, Horizontal Exits
Fire-protection-rated glazing shall be permitted as vision panels in self-closing swinging fire door assemblies serving as horizontal exits ...
Building Code 2018 of Illinois > 7 Fire and Smoke Protection Features > 716 Opening Protectives > 716.2 Fire Door Assemblies > 716.2.5 Glazing in Fire Door Assemblies > 716.2.5.1 Size Limitations > 716.2.5.1.2 Fire-Protection-Rated Glazing in Door Assemblies in Fire Walls and Fire Barriers Rated Greater Than 1 Hour > 716.2.5.1.2.1 Horizontal Exits
712.1 Fire and Smoke Protection Features, General
Horizontal fire door assemblies used to protect openings in fire-resistance-rated horizontal assemblies shall be tested in accordance ...
Building Code 2021 of Illinois > 7 Fire and Smoke Protection Features > 712 Vertical Openings > 712.1 General
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING