• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

P3005.2.1 Horizontal Drains and Building Drains

Residential Code 2018 of Kansas > 30 Sanitary Drainage > P3005 Drainage System > P3005.2 Cleanouts Required > P3005.2.1 Horizontal Drains and Building Drains
JUMP TO FULL CODE CHAPTER
Horizontal drainage pipes in buildings shall have cleanouts located at intervals of not more than 100 feet (30 480 mm). Building drains shall have cleanouts located at intervals of not more than 100 feet (30 480 mm) except where manholes are used instead of cleanouts, the manholes shall be located at intervals of not more than 400 feet (122 m). The interval length shall be measured from the cleanout or manhole opening, along the developed length of the piping to the next drainage fitting providing access for cleaning, the end of the horizontal drain or the end of the building drain.
Exception: Horizontal fixture drain piping serving a nonremovable trap shall not be required to have a cleanout for the section of piping between the trap and the vent connection for such trap.

Related Code Sections


708.1.1 Sanitary Drainage, Horizontal Drains and Building Drains
Horizontal drainage pipes in buildings shall have cleanouts located at intervals of not more than 100 feet (30 480 mm). Building drains shall have ...
Plumbing Code 2018 of Kansas > 7 Sanitary Drainage > 708 Cleanouts > 708.1 Cleanouts Required > 708.1.1 Horizontal Drains and Building Drains
P3005.2.1 Sanitary Drainage, Horizontal Drains and Building Drains
Horizontal drainage pipes in buildings shall have cleanouts located at intervals of not more than 100 feet (30 480 mm). Building drains shall have ...
Residential Code 2018 of Kansas > 30 Sanitary Drainage > P3005 Drainage System > P3005.2 Cleanouts Required > P3005.2.1 Horizontal Drains and Building Drains
P3111.2.2 Vents, Vent Connection
to a horizontal drain or building drain that serves vented fixtures located on the same floor. Combination waste and vent systems connecting to building ...
Residential Code 2018 of Kansas > 31 Vents > P3111 Combination Waste and Vent System > P3111.2 Installation > P3111.2.2 Vent Connection
P3008.1 Sanitary Drainage, Where Required
, the fixtures shall be protected by a backwater valve installed in the building drain , branch of the building drain or horizontal branch serving ...
Residential Code 2018 of Kansas > 30 Sanitary Drainage > P3008 Backwater Valves > P3008.1 Where Required
710.1 Sanitary Drainage, Maximum Fixture Unit Load
The maximum number of drainage fixture units connected to a given size of building sewer , building drain or horizontal branch ...
Plumbing Code 2018 of Kansas > 7 Sanitary Drainage > 710 Drainage System Sizing > 710.1 Maximum Fixture Unit Load
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING