• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

P-904.4.2 Horizontal Branch Size

Philadelphia Plumbing Code > 9 Soil and Waste Piping > P-904 Sizes > P-904.4 Maximum Fixture-Unit Load > P-904.4.2 Horizontal Branch Size
JUMP TO FULL CODE CHAPTER
The size of the horizontal branch from the base of the soil or waste stack connected to the house drain is determined by the fixture-units and gradient fall.

Related Code Sections


P-904.4.2 Soil and Waste Piping, Horizontal Branch Size
The size of the horizontal branch from the base of the soil or waste stack connected to the house drain is determined by the fixture-units ...
Philadelphia Plumbing Code > 9 Soil and Waste Piping > P-904 Sizes > P-904.4 Maximum Fixture-Unit Load > P-904.4.2 Horizontal Branch Size
P-919.2.6 Vents, Horizontal Branch Size
The size of the horizontal branch from the base of the soil or waste stack connected to the house drain is determined by the fixture units ...
Plumbing Code 2018 of Philadelphia > 9 Vents > P-919 Philadelphia Single-Stack Waste and Vent System > P-919.2 Drainage System Sizing > P-919.2.6 Horizontal Branch Size
914.3 Vents, Slope and Size of Horizontal Branch
). The entire length of the vent section of the horizontal branch drain shall be sized for the total drainage discharge to the branch ...
Plumbing Code 2018 of Philadelphia > 9 Vents > 914 Circuit Venting > 914.3 Slope and Size of Horizontal Branch
P3110.3 Vents, Slope and Size of Horizontal Branch
). The entire length of the vent section of the horizontal branch drain shall be sized for the total drainage discharge to the branch in accordance ...
Philadelphia Residential Code > 31 Vents > P3110 Circuit Venting > P3110.3 Slope and Size of Horizontal Branch
917.3 Vents, Branch Size
Horizontal branches connecting to a single-stack vent system shall be sized in accordance with Table 710.1(2). Not more than one water closet shall ...
Plumbing Code 2018 of Philadelphia > 9 Vents > 917 Single-Stack Vent System > 917.3 Branch Size
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING