If a horizontal branch connects to the stack within 2 feet (610 mm) above or below a vertical stack offset, and the offset is located more than four branch intervals below the top of the stack, the offset shall be vented in accordance with Section 907.
711.1.1 Omission of Vents for Vertical Stack Offsets
Vents for vertical offsets required by Section 711.1 shall not be required where the stack and its offset are sized as a building drain [see Table 710.1(1)].

Related Code Sections

Section 711 Sanitary Drainage, Offsets in Drainage Piping in Buildings of Five Stories or More
If a horizontal branch connects to the stack within 2 feet (610 mm) above or below a vertical stack offset, and the offset is located more than four ...
711.3 Sanitary Drainage, Horizontal Stack Offsets
A stack with a horizontal offset located more than four branch intervals below the top of the stack shall be vented in accordance with Section 915 ...