// CODE SNIPPET
Section 8-810 Hollow Clay Tile
JUMP TO FULL CODE CHAPTER
The historical performance of hollow clay tile in past earthquakes shall be carefully considered in evaluating walls of hollow clay tile construction. Hollow clay tile bearing walls shall be evaluated and strengthened as appropriate for lateral loads and their ability to maintain support of gravity loads. Suitable protective measures shall be provided to prevent blockage of exit stairways, stairway enclosures, exit ways and public ways as a result of an earthquake.
Related Code Sections
Section 8-810 Archaic Materials and Methods of Construction, Hollow Clay Tile
The historical performance of hollow clay tile in past earthquakes shall be carefully considered in evaluating walls of hollow clay tile construction ...
California Historical Building Code 2019 > 8-8 Archaic Materials and Methods of Construction > 8-810 Hollow Clay Tile
Section 8-810 Archaic Materials and Methods of Construction, Hollow Clay Tile
The historical performance of hollow clay tile in past earthquakes shall be carefully considered in evaluating walls of hollow clay tile construction ...
California Historical Building Code 2016 > 8-8 Archaic Materials and Methods of Construction > 8-810 Hollow Clay Tile
A106.3.2.2 Guidelines for the Seismic Retrofit of Existing Buildings, Grouted or Ungrouted Hollow Concrete or Clay Block and Structural Hollow Clay Tile
Grouted or ungrouted hollow concrete or clay block and structural hollow clay tile shall be laid in a running bond pattern ...
California Existing Building Code 2016 > A Guidelines for the Seismic Retrofit of Existing Buildings > A106 Materials Requirements > A106.3 Existing Unreinforced Masonry > A106.3.2 Lay-Up of Walls > A106.3.2.2 Grouted or Ungrouted Hollow Concrete or Clay Block and Structural Hollow Clay Tile
10.1.1.1 Seismic Evaluation Procedures for Hospital Buildings, Masonry Partitions
There are no unbraced unreinforced masonry or hollow clay tile partitions in critical care areas, clinical laboratory service spaces, pharmaceutical ...
California Administrative Code 2019 > 6 Seismic Evaluation Procedures for Hospital Buildings > 10 Evaluation of Elements That Are Not Part of the Lateral-Force-Resisting System > 10.1 Nonstructural Walls > 10.1.1 Partitions > 10.1.1.1 Masonry Partitions
10.1.1.1 Seismic Evaluation Procedures for Hospital Buildings, Masonry Partitions
There are no unbraced unrein-forced masonry or hollow clay tile partitions in critical care areas, clinical laboratory service spaces, pharmaceutical ...
California Administrative Code 2016 > 6 Seismic Evaluation Procedures for Hospital Buildings > 10 Evaluation of Elements That Are Not Part of the Lateral-Force-Resisting System > 10.1 Nonstructural Walls > 10.1.1 Partitions > 10.1.1.1 Masonry Partitions