1926.1431(o) Hoisting Personnel in Drill Shafts
JUMP TO FULL CODE CHAPTER
When hoisting employees into and out of drill shafts that are up to and including 8 feet in diameter, all of the following requirements must be met:
The employee must be in either a personnel platform or on a boatswain's chair.
If using a personnel platform, paragraphs (a) through (n) of this section apply.
The following paragraphs of this section apply: (a), (c), (d)(1), (d)(3), (d)(4), (e)(1), (e)(2), (e)(3), (f)(1), (f)(2)(i), (f)(3)(i), (g), (h), (k)(1), (k)(6), (k)(8), (k)(9), (k)(11)(i), (m), (n). Where the terms "personnel platform" or "platform" are used in these paragraphs, substitute them with "boatswain's chair."
The employee must be hoisted in a slow, controlled descent and ascent.
The employee must use personal fall protection equipment, including a full body harness, attached independent of the crane/derrick.
The fall protection equipment must meet the applicable requirements in § 1926.502.
The boatswain's chair itself (excluding the personal fall arrest system anchorages), must be capable of supporting, without failure, its own weight and at least five times the maximum intended load.
A signal person must be stationed at the shaft opening.
Related Code Sections
1926.1431(o) Cranes & Derricks in Construction, Hoisting Personnel in Drill Shafts
When hoisting employees into and out of drill shafts that are up to and including 8 feet in diameter, all of the following requirements must be met ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel > 1926.1431(o) Hoisting Personnel in Drill Shafts
1926.1431(o)(3)(iii) Cranes & Derricks in Construction,
The employee must be hoisted in a slow, controlled descent and ascent ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel > 1926.1431(o) Hoisting Personnel in Drill Shafts > 1926.1431(o)(3) If Using a Boatswain's Chair: > 1926.1431(o)(3)(iii)
1926.1431(o)(3)(iv) Cranes & Derricks in Construction,
The employee must use personal fall protection equipment, including a full body harness, attached independent of the crane/derrick ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel > 1926.1431(o) Hoisting Personnel in Drill Shafts > 1926.1431(o)(3) If Using a Boatswain's Chair: > 1926.1431(o)(3)(iv)
1926.1431(o)(3)(v) Cranes & Derricks in Construction,
The fall protection equipment must meet the applicable requirements in § 1926.502 ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel > 1926.1431(o) Hoisting Personnel in Drill Shafts > 1926.1431(o)(3) If Using a Boatswain's Chair: > 1926.1431(o)(3)(v)
1926.1431(o)(3)(vi) Cranes & Derricks in Construction,
The boatswain's chair itself (excluding the personal fall arrest system anchorages), must be capable of supporting, without failure, its own weight ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel > 1926.1431(o) Hoisting Personnel in Drill Shafts > 1926.1431(o)(3) If Using a Boatswain's Chair: > 1926.1431(o)(3)(vi)