• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1926.1431(r) Hoisting Personnel for Marine Transfer

OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel > 1926.1431(r) Hoisting Personnel for Marine Transfer
JUMP TO FULL CODE CHAPTER
When hoisting employees solely for transfer to or from a marine worksite, the following requirements must be met:

1926.1431(r)(1)

The employee must be in either a personnel platform or a marine-hoisted personnel transfer device.

1926.1431(r)(2)

If using a personnel platform, paragraphs (a) through (n) of this section apply.

1926.1431(r)(3) If Using a Marine-Hoisted Personnel Transfer Device:

1926.1431(r)(3)(i)

The following paragraphs of this section apply: (a), (c)(2), (d)(1), (d)(3), (d)(4), (e)(1) through (5), (e)(12), (f)(1), (g), (h), (j), (k)(1), (k)(8), (k)(9), (k)(10)(ii), (k)(11)(i), (k)(12), (m), and (n). Where the terms "personnel platform" or "platform" are used in these paragraphs, substitute them with "marine-hoisted personnel transfer device."

1926.1431(r)(3)(iii)

The number of workers occupying the transfer device must not exceed the maximum number it was designed to hold.

1926.1431(r)(3)(iv)

Each employee must wear a U.S. Coast Guard personal flotation device approved for industrial use.

1926.1431(r)(3)(ii)

The transfer device must be used only for transferring workers.

Related Code Sections


1926.1431(r) Cranes & Derricks in Construction, Hoisting Personnel for Marine Transfer
). Where the terms "personnel platform" or "platform" are used in these paragraphs, substitute them with "marine-hoisted personnel transfer device ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel > 1926.1431(r) Hoisting Personnel for Marine Transfer
1926.1431(r)(3)(iii) Cranes & Derricks in Construction,
The number of workers occupying the transfer device must not exceed the maximum number it was designed to hold ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel > 1926.1431(r) Hoisting Personnel for Marine Transfer > 1926.1431(r)(3) If Using a Marine-Hoisted Personnel Transfer Device: > 1926.1431(r)(3)(iii)
1926.1431(r)(3)(iv) Cranes & Derricks in Construction,
Each employee must wear a U.S. Coast Guard personal flotation device approved for industrial use ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel > 1926.1431(r) Hoisting Personnel for Marine Transfer > 1926.1431(r)(3) If Using a Marine-Hoisted Personnel Transfer Device: > 1926.1431(r)(3)(iv)
1926.1431(b)(2)(iii) Cranes & Derricks in Construction,
Solely for transfer to or from a marine worksite in a marine-hoisted personnel transfer device ( see paragraph (r) of this section for requirements ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel > 1926.1431(b) Use of Personnel Platform > 1926.1431(b)(2) Exceptions: > 1926.1431(b)(2)(iii)
1926.1431(b)(2) Cranes & Derricks in Construction, Exceptions:
to or from a marine worksite in a marine-hoisted personnel transfer device ( see paragraph (r) of this section for requirements for hoisting these employees ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel > 1926.1431(b) Use of Personnel Platform > 1926.1431(b)(2) Exceptions:
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE