1926.1435(e)(5)(vi) Hoist Line Pull Limiting Device
JUMP TO FULL CODE CHAPTER
The capacity of the hoist must be limited to prevent overloading, including each individual gear ratio if equipped with a multiple speed hoist transmission. Temporary alternative measures: The operator must ensure that the weight of the load does not exceed the capacity of the hoist (including for each individual gear ratio if equipped with a multiple speed hoist transmission).
Related Code Sections
1926.1435(e)(5)(vi) Cranes & Derricks in Construction, Hoist Line Pull Limiting Device
The capacity of the hoist must be limited to prevent overloading, including each individual gear ratio if equipped with a multiple speed hoist ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1435 Tower Cranes > 1926.1435(e) Operational Aids > 1926.1435(e)(5) Category I Operational Aids and Alternative Measures > 1926.1435(e)(5)(vi) Hoist Line Pull Limiting Device
1926.551(l) Helicopters, Hoists, Elevators, and Conveyors, Ground Lines
Hoist wires or other gear, except for pulling lines or conductors that are allowed to "pay out" from a container or roll off a reel, shall ...
OSHA 1926 Construction > N Helicopters, Hoists, Elevators, and Conveyors > 1926.551 Helicopters > 1926.551(l) Ground Lines
1926.800(t)(4)(i) Underground Construction, Caissons, Cofferdams, and Compressed Air,
of the hoist's rated line pull. A broken-rope safety, safety catch, or arrestment device is not a permissible means of stopping under this paragraph ...
OSHA 1926 Construction > S Underground Construction, Caissons, Cofferdams, and Compressed Air > 1926.800 Underground Construction > 1926.800(t) Hoisting Unique to Underground Construction > 1926.800(t)(4) Additional Requirements for Personnel Hoists > 1926.800(t)(4)(i)
1926.964(b)(6) Electric Power Transmission and Distribution, Load Ratings
The employer shall ensure that employees do not exceed load ratings of stringing lines, pulling lines, conductor grips, load-bearing hardware ...
OSHA 1926 Construction > V Electric Power Transmission and Distribution > 1926.964 Overhead Lines and Live-Line Barehand Work > 1926.964(b) Installing and Removing Overhead Lines > 1926.964(b)(6) Load Ratings
1926.1431(d)(5) Cranes & Derricks in Construction, Devices
have a system, other than the load line hoist brake, which regulates the lowering rate of speed of the hoist mechanism. This system or device must ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel > 1926.1431(d) Equipment Criteria > 1926.1431(d)(5) Devices