// CODE SNIPPET
1910.1030(e)(3) HIV and HBV Research Laboratories Shall Meet the Following Criteria:
JUMP TO FULL CODE CHAPTER
Each laboratory shall contain a facility for hand washing and an eye wash facility which is readily available within the work area.
An autoclave for decontamination of regulated waste shall be available.
Related Code Sections
1910.1030(e)(3) Toxic and Hazardous Substances, HIV and HBV Research Laboratories Shall Meet the Following Criteria:
Each laboratory shall contain a facility for hand washing and an eye wash facility which is readily available within the work area ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1030 Bloodborne Pathogens > 1910.1030(e) HIV and HBV Research Laboratories and Production Facilities > 1910.1030(e)(3) HIV and HBV Research Laboratories Shall Meet the Following Criteria:
1910.1030(e)(2)(i) Toxic and Hazardous Substances, Standard Microbiological Practices
All regulated waste shall either be incinerated or decontaminated by a method such as autoclaving known to effectively destroy bloodborne pathogens ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1030 Bloodborne Pathogens > 1910.1030(e) HIV and HBV Research Laboratories and Production Facilities > 1910.1030(e)(2) Research Laboratories and Production Facilities Shall Meet the Following Criteria: > 1910.1030(e)(2)(i) Standard Microbiological Practices
1910.1030(e)(2)(ii)(C) Toxic and Hazardous Substances,
been advised of the potential biohazard, who meet any specific entry requirements, and who comply with all entry and exit procedures shall be allowed ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1030 Bloodborne Pathogens > 1910.1030(e) HIV and HBV Research Laboratories and Production Facilities > 1910.1030(e)(2) Research Laboratories and Production Facilities Shall Meet the Following Criteria: > 1910.1030(e)(2)(ii) Special Practices > 1910.1030(e)(2)(ii)(C)
1910.1030(e)(2)(ii)(M) Toxic and Hazardous Substances,
be advised of potential hazards, shall be required to read instructions on practices and procedures, and shall be required to follow them ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1030 Bloodborne Pathogens > 1910.1030(e) HIV and HBV Research Laboratories and Production Facilities > 1910.1030(e)(2) Research Laboratories and Production Facilities Shall Meet the Following Criteria: > 1910.1030(e)(2)(ii) Special Practices > 1910.1030(e)(2)(ii)(M)
1910.1030(e)(2)(ii)(J) Toxic and Hazardous Substances,
Hypodermic needles and syringes shall be used only for parenteral injection and aspiration of fluids from laboratory animals and diaphragm bottles ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1030 Bloodborne Pathogens > 1910.1030(e) HIV and HBV Research Laboratories and Production Facilities > 1910.1030(e)(2) Research Laboratories and Production Facilities Shall Meet the Following Criteria: > 1910.1030(e)(2)(ii) Special Practices > 1910.1030(e)(2)(ii)(J)