R802.4.3 Hips and Valleys
JUMP TO FULL CODE CHAPTER
Hip and valley rafters shall be not less than 2 inches (51 mm) nominal in thickness and not less in depth than the cut end of the rafter. Hip and valley rafters shall be supported at the ridge by a brace to a bearing partition or be designed to carry and distribute the specific load at that point.
Related Code Sections
R802.4.3 Roof-Ceiling Construction, Hips and Valleys
Hip and valley rafters shall be not less than 2 inches (51 mm) nominal in thickness and not less in depth than the cut end of the rafter. Hip ...
Residential Code 2018 of Kansas > 8 Roof-Ceiling Construction > R802 Wood Roof Framing > R802.4 Rafters > R802.4.3 Hips and Valleys
2308.7.3 Wood, Ceiling Joist and Rafter Framing
at ridges and not less in depth than the cut end of the rafter. At valleys and hips, there shall be a single valley or hip rafter not less than 2-inch (51 ...
Building Code 2018 of Kansas > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.7 Roof and Ceiling Framing > 2308.7.3 Ceiling Joist and Rafter Framing
1507.2.8.2 Roof Assemblies and Rooftop Structures, Valleys
Valley linings shall be installed in accordance with the manufacturer's instructions before applying shingles. Valley linings of the following types ...
Building Code 2018 of Kansas > 15 Roof Assemblies and Rooftop Structures > 1507 Requirements for Roof Coverings > 1507.2 Asphalt Shingles > 1507.2.8 Flashings > 1507.2.8.2 Valleys
R905.2.8.2 Roof Assemblies, Valleys
Valley linings shall be installed in accordance with the manufacturer's instructions before applying shingles. Valley linings of the following types ...
Residential Code 2018 of Kansas > 9 Roof Assemblies > R905 Requirements for Roof Coverings > R905.2 Asphalt Shingles > R905.2.8 Flashing > R905.2.8.2 Valleys
8.6.4.1.4.5* Installation Requirements,
The requirements of 8.6.4.1.4.3 or 8.6.4.1.4.4 shall not apply to sprinklers installed at the corner of the eave of a hip type roof where located ...
Standard for the Installation of Sprinkler Systems 2016 of Kansas > 8 Installation Requirements > 8.6 Standard Pendent and Upright Spray Sprinklers > 8.6.4 Deflector Position (Standard Pendent and Upright Spray Sprinklers) > 8.6.4.1 Distance Below Ceilings > 8.6.4.1.4 > 8.6.4.1.4.5*