// CODE SNIPPET
R804.3.3.3 Hip Support Columns
JUMP TO FULL CODE CHAPTER
Hip support columns shall be used to support hip members at the ridge. A hip support column shall consist of a pair of C-shape members, with a minimum size determined in accordance with Table R804.3.3.3. The C-shape members shall be connected at a maximum spacing of 24 inches (610 mm) on center to form a box using minimum 3-inch by 33-mil (76 mm by 0.84 mm) strap connected to each of the flanges of the C-shape members with three-No. 10 screws. Hip support columns shall have a continuous load path to the foundation and shall be supported at the ceiling line by an interior wall or by an approved design for a supporting element.
HIP SUPPORT COLUMN SIZES
BUILDING WIDTH (feet) | HIP SUPPORT COLUMN DESIGNATIONa, b | |||
Equivalent ground snow load (psf) | ||||
0 to 20 | 21 to 30 | 31 to 50 | 51 to 70 | |
24 | 2-350S162-33 | 2-350S162-33 | 2-350S162-43 | 2-350S162-54 |
28 | 2-350S162-54 | 2-550S162-54 | 2-550S162-68 | 2-550S162-68 |
32 | 2-550S162-68 | 2-550S162-68 | 2-550S162-97 | — |
36 | 2-550S162-97 | — | — | — |
40 | — | — | — | — |
For SI: 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
- Box shape column only in accordance with Figure R804.3.3.4(2).
- 33-ksi steel for 33- and 43-mil material; 50-ksi steel for thicker material.
Related Code Sections
R804.3.3.3 Roof-Ceiling Construction, Hip Support Columns
Hip support columns shall be used to support hip members at the ridge. A hip support column shall consist of a pair of C-shape members ...
Minnesota Residential Code 2015 > 8 Roof-Ceiling Construction > R804 Steel Roof Framing > R804.3 Roof Construction > R804.3.3 Hip Framing > R804.3.3.3 Hip Support Columns
R802.4.3 Roof-Ceiling Construction, Hips and Valleys
Hip and valley rafters shall be not less than 2 inches (51 mm) nominal in thickness and not less in depth than the cut end of the rafter. Hip ...
2020 Minnesota Residential Code > 8 Roof-Ceiling Construction > R802 Wood Roof Framing > R802.4 Rafters > R802.4.3 Hips and Valleys
602.4.1 Types of Construction, Columns
Wood columns shall be sawn or glued laminated and shall be not less than 8 inches (203 mm), nominal, in any dimension where supporting floor loads ...
Minnesota Building Code 2015 > 6 Types of Construction > 602 Construction Classification > 602.4 Type IV > 602.4.1 Columns
R802.4.4 Roof-Ceiling Construction, Rafter Supports
Where the roof pitch is less than 3:12 (25-percent slope), structural members that support rafters, such as ridges, hips and valleys, shall ...
2020 Minnesota Residential Code > 8 Roof-Ceiling Construction > R802 Wood Roof Framing > R802.4 Rafters > R802.4.4 Rafter Supports
2304.10.1 Wood, Columns
, to transfer horizontal loads across joints. Wood bolsters shall not be placed on tops of columns unless the columns support roof loads only ...
Minnesota Building Code 2015 > 23 Wood > 2304 General Construction Requirements > 2304.10 Heavy Timber Construction > 2304.10.1 Columns