• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

Section 2325 High-Velocity Hurricane Zones— Wood Supporting Masonry

2017 FBC - Building, 6th edition > 23 Wood > 2325 High-Velocity Hurricane Zones— Wood Supporting Masonry
JUMP TO FULL CODE CHAPTER

2325.1

Wood shall not support masonry or concrete except as permitted in Section 2325.2.

2325.2

Wood foundation piles may be used to support concrete or masonry.

2325.3

Reserved.

Related Code Sections


Section 2325 Wood, High-Velocity Hurricane Zones— Wood Supporting Masonry
Wood shall not support masonry or concrete except as permitted in Section 2325.2 ...
2014 FBC - Building, 5th edition > 23 Wood > 2325 High-Velocity Hurricane Zones— Wood Supporting Masonry
Section 2325 Wood, High-Velocity Hurricane Zones— Wood Supporting Masonry
Wood shall not support masonry or concrete except as permitted in Section 2325.2 ...
2017 FBC - Building, 6th edition > 23 Wood > 2325 High-Velocity Hurricane Zones— Wood Supporting Masonry
Section 2325 Wood, High-Velocity Hurricane Zones—Wood Supporting Masonry
Wood shall not support masonry or concrete except as permitted in Section 2325.2 ...
2020 FBC - Building, 7th edition > 23 Wood > 2325 High-Velocity Hurricane Zones—Wood Supporting Masonry
2325.1 Wood,
Wood shall not support masonry or concrete except as permitted in Section 2325.2 ...
2020 FBC - Building, 7th edition > 23 Wood > 2325 High-Velocity Hurricane Zones—Wood Supporting Masonry > 2325.1
2325.3 Wood,
Reserved ...
2017 FBC - Building, 6th edition > 23 Wood > 2325 High-Velocity Hurricane Zones— Wood Supporting Masonry > 2325.3
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE