Section 2328 High-Velocity Hurricane Zones— Wood Fences
JUMP TO FULL CODE CHAPTER
Fences not exceeding 6 feet (1829 mm) in height, shall be constructed to meet the following minimum requirements: from nominal 4-inch by 4-inch by 8-feet-long (102 mm by 102 mm by 2438 mm) posts No. 2 grade or better spaced 4-feet (1219 mm) on center, and embedded 2 feet (610 mm) into a concrete footing 10 inches (254 mm) in diameter and 2-feet (610 mm) deep.
Fences not exceeding 5 feet (1524 mm) or 4 feet (1219 mm) in height shall be constructed as provided in Section 2328.2, except that the spacing of posts may be increased to 5-feet (1524 mm) and 6-feet (1829 mm) on center for these heights, respectively.
Related Code Sections
Section 2328 Wood, High-Velocity Hurricane Zones— Wood Fences
Wood fences, so located on a property that by zoning regulations they cannot be used as a wall of a building, shall be constructed to meet ...
Section 2328 Wood, High-Velocity Hurricane Zone— Wood Fences
Wood fences, so located on a property that by zoning regulations they cannot be used as a wall of a building, shall be constructed to meet ...
Section 2328 Wood, High-Velocity Hurricane Zones—Wood Fences
Wood fences, so located on a property that by zoning regulations they cannot be used as a wall of a building, shall be constructed to meet ...
2328.2 Wood,
Fences not exceeding 6 feet (1829 mm) in height, shall be constructed to meet the following minimum requirements: from nominal 4-inch by 4-inch by 8 ...
2020 FBC - Building, 7th edition > 23 Wood > 2328 High-Velocity Hurricane Zones—Wood Fences > 2328.2
2328.3 Wood,
Fences not exceeding 5 feet (1524 mm) or 4 feet (1219 mm) in height shall be constructed as provided in Section 2328.2, except that the spacing ...
2017 FBC - Building, 6th edition > 23 Wood > 2328 High-Velocity Hurricane Zones— Wood Fences > 2328.3