1808.4.1.4 High Strain, Dynamic Compressive Test Methods
JUMP TO FULL CODE CHAPTER
High strain, dynamic compressive test methods performed in accordance with ASTM D 4945 shall be permitted to be used where three or more load tests are required and subject to the approval of the commissioner. In such case, at least one high strain dynamic test shall be performed as a calibration on a static load tested pile or nearby pile driven to comparable resistance. No more than one-half of the required number of load tests may be performed by high strain dynamic methods. High strain dynamic tests shall be performed under the supervision of an engineer experienced in the methods used. The number of high strain dynamic tests shall be at least twice the number of replaced static load tests.
Related Code Sections
1808.4.1.4 Soils and Foundations, High Strain, Dynamic Compressive Test Methods
High strain, dynamic compressive test methods performed in accordance with ASTM D 4945 shall be permitted to be used where three or more load tests ...
NYC Building Code 2014 > 18 Soils and Foundations > 1808 Deep Foundations > 1808.4 Load Tests > 1808.4.1 Compressive Load Tests > 1808.4.1.4 High Strain, Dynamic Compressive Test Methods
Chapter 35 Referenced Standards [PDF] (page 8)
Specification for Coal Tar Glass Felt Used in Roofing and Waterproofing Test Method for High-Strain Dynamic Testing of Piles P Specification for Reinforced ...
2105.2.2.2 Masonry, Prism Test Method
The compressive strength of masonry shall be determined by the prism test method: Where specified in the construction documents. Where masonry ...
NYC Building Code 2014 > 21 Masonry > 2105 Quality Assurance > 2105.2 Acceptance Relative to Strength Requirements > 2105.2.2 Determination of Compressive Strength > 2105.2.2.2 Prism Test Method
2105.2.2.2 Masonry, Prism Test Method
The compressive strength of masonry shall be determined by the prism test method: 1. Where specified in the construction documents ...
NYC Building Code 2008 > 21 Masonry > 2105 Quality Assurance > 2105.2 Acceptance Relative to Strength Requirements > 2105.2.2 Determination of Compressive Strength > 2105.2.2.2 Prism Test Method
1626.9.2 Structural Design, Dynamic Inelastic Analysis
For analysis of this type, dynamic effects of member loss or specific local loads shall be considered. The structure does not need to remain elastic ...
NYC Building Code 2008 > 16 Structural Design > 1626 Structural Integrity—Key Element Analysis > 1626.9 Analysis Procedures > 1626.9.2 Dynamic Inelastic Analysis