Where drinking fountains are provided on an exterior site, on a floor or within a secured area, the drinking fountains shall be provided in accordance with Sections 410.3.1 and 410.3.2.
[BE] 410.3.1 Minimum Number
Not fewer than two drinking fountains shall be provided. One drinking fountain shall comply with the requirements for people who use a wheelchair and one drinking fountain shall comply with the requirements for standing persons.
Exceptions:
  1. A single drinking fountain with two separate spouts that complies with the requirements for people who use a wheelchair and standing persons shall be permitted to be substituted for two separate drinking fountains.
  2. Where drinking fountains are primarily for children's use, the drinking fountains for people using wheelchairs shall be permitted to comply with the children's provisions in ICC A117.1 and drinking fountains for standing children shall be permitted to provide the spout at 30 inches (762 mm) minimum above the floor.
[BE] 410.3.2 More Than the Minimum Number
Where more than the minimum number of drinking fountains specified in Section  410.3.1 is provided, 50 percent of the total number of drinking fountains provided shall comply with the requirements for persons who use a wheelchair and 50 percent of the total number of drinking fountains provided shall comply with the requirements for standing persons.
Exceptions:
  1. Where 50 percent of the drinking fountains yields a fraction, 50 percent shall be permitted to be rounded up or down, provided that the total number of drinking fountains complying with this section equals 100 percent of the drinking fountains.
  2. Where drinking fountains are primarily for children's use, drinking fountains for people using wheelchairs shall be permitted to comply with the children's provisions in ICC A117.1 and drinking fountains for standing children shall be permitted to provide the spout at 30 inches (762 mm) minimum above the floor.
Upcodes Diagrams

Related Code Sections

410.3 Fixtures, Faucets and Fixture Fittings, High and Low Drinking Fountains
Where drinking fountains are provided on an exterior site, on a floor or within a secured area, the drinking fountains shall be provided ...
1109.5 Accessibility, Drinking Fountains
Where drinking fountains are provided on an exterior site, on a floor or within a secured area, the drinking fountains shall be provided ...
1109.5 Accessibility, Drinking Fountains
Where drinking fountains are provided on an exterior site, on a floor or within a secured area, the drinking fountains shall be provided ...
1110.5 Accessibility, Drinking Fountains
Where drinking fountains are provided on an exterior site, on a floor or within a secured area, the drinking fountains shall be provided ...