1607.7.3 Heavy Vehicle Garages
JUMP TO FULL CODE CHAPTER
Garages designed to accommodate vehicles that exceed a 10,000-pound (4536 kg) gross vehicle weight rating, shall be designed using the live loading specified by Section 1607.7.1. For garages the design for impact and fatigue is not required.
Exception: The vehicular live loads and load placement are allowed to be determined using the actual vehicle weights for the vehicles allowed onto the garage floors, provided such loads and placement are based on rational engineering principles and are approved by the building official, but shall not be less than 50 psf (2.9 kN/m2). This live load shall not be reduced.
Related Code Sections
1607.7.3 Structural Design, Heavy Vehicle Garages
Garages designed to accommodate vehicles that exceed a 10,000-pound (4536 kg) gross vehicle weight rating, shall be designed using the live loading ...
2017 FBC - Building, 6th edition > 16 Structural Design > 1607 Live Loads > 1607.7 Heavy Vehicle Loads > 1607.7.3 Heavy Vehicle Garages
1607.7.3 Structural Design, Heavy Vehicle Garages
Garages designed to accommodate vehicles that exceed a 10,000 pound (4536 kg) gross vehicle weight rating, shall be designed using the live loading ...
2014 FBC - Building, 5th edition > 16 Structural Design > 1607 Live Loads > 1607.7 Heavy Vehicle Loads > 1607.7.3 Heavy Vehicle Garages
1607.7.3 Structural Design, Heavy Vehicle Garages
Garages designed to accommodate vehicles that exceed a 10,000-pound (4536 kg) gross vehicle weight rating, shall be designed using the live loading ...
2020 FBC - Building, 7th edition > 16 Structural Design > 1607 Live Loads > 1607.7 Heavy Vehicle Loads > 1607.7.3 Heavy Vehicle Garages
1607.7.5 Structural Design, Posting
The maximum weight of vehicles allowed into or on a garage or other structure shall be posted by the owner or the owner's authorized agent ...
2020 FBC - Building, 7th edition > 16 Structural Design > 1607 Live Loads > 1607.7 Heavy Vehicle Loads > 1607.7.5 Posting
1607.10.1.3 Structural Design, Passenger Vehicle Garages
The live loads shall not be reduced in passenger vehicle garages. Exception: The live loads for members supporting two or more floors ...
2017 FBC - Building, 6th edition > 16 Structural Design > 1607 Live Loads > 1607.10 Reduction in Uniform Live Loads > 1607.10.1 Basic Uniform Live Load Reduction > 1607.10.1.3 Passenger Vehicle Garages