1607.11.1.2 Heavy Live Loads
JUMP TO FULL CODE CHAPTER
Live loads that exceed 100 psf (4.79 kN/m2) shall not be reduced.
Exceptions:
- The live loads for members supporting two or more floors are permitted to be reduced by not greater than 20 percent, but the live load shall be not less than L as calculated in Section 1607.11.1.
- For uses other than storage, where approved, additional live load reductions shall be permitted where shown by the registered design professional that a rational approach has been used and that such reductions are warranted.
Related Code Sections
1607.10.1.2 Structural Design, Heavy Live Loads
Live loads that exceed 100 psf (4.79 kN/m 2 ) shall not be reduced.
Exceptions:
The live loads for members supporting two or more floors ...
Building Code 2015 of Wyoming > 16 Structural Design > 1607 Live Loads > 1607.10 Reduction in Uniform Live Loads > 1607.10.1 Basic Uniform Live Load Reduction > 1607.10.1.2 Heavy Live Loads
1607.11.1.2 Structural Design, Heavy Live Loads
Live loads that exceed 100 psf (4.79 kN/m 2 ) shall not be reduced. Exceptions: The live loads for members supporting two or more floors ...
Building Code 2018 of Wyoming > 16 Structural Design > 1607 Live Loads > 1607.11 Reduction in Uniform Live Loads > 1607.11.1 Basic Uniform Live Load Reduction > 1607.11.1.2 Heavy Live Loads
1607.7.2 Structural Design, Fire Truck and Emergency Vehicles
of the vehicles as stipulated and approved by the building official . The live loading specified in Section 1607.7.1 ...
Building Code 2018 of Wyoming > 16 Structural Design > 1607 Live Loads > 1607.7 Heavy Vehicle Loads > 1607.7.2 Fire Truck and Emergency Vehicles
1607.7.4 Structural Design, Forklifts and Movable Equipment
or equipment load and the individual wheel loads for the anticipated vehicles as specified by the owner of the facility. These loads shall be posted ...
Building Code 2015 of Wyoming > 16 Structural Design > 1607 Live Loads > 1607.7 Heavy Vehicle Loads > 1607.7.4 Forklifts and Movable Equipment
1607.7.4 Structural Design, Forklifts and Movable Equipment
or equipment load and the individual wheel loads for the anticipated vehicles as specified by the owner of the facility. These loads shall be posted ...
Building Code 2018 of Wyoming > 16 Structural Design > 1607 Live Loads > 1607.7 Heavy Vehicle Loads > 1607.7.4 Forklifts and Movable Equipment