1808.2.19 Heaved Piles
JUMP TO FULL CODE CHAPTER
Piles that have heaved during the driving of adjacent piles shall be redriven as necessary to develop the required capacity and penetration, or the capacity of the pile shall be verified by load tests in accordance with Section 1808.2.8.3.
Related Code Sections
1808.2.19 Soils and Foundations, Heaved Piles
Piles that have heaved during the driving of adjacent piles shall be redriven as necessary to develop the required capacity and penetration ...
2010 Building Code of NY > 18 Soils and Foundations > 1808 Pier and Pile Foundations > 1808.2 Piers and Piles-General Requirements > 1808.2.19 Heaved Piles
1810.2.3 Soils and Foundations, Installation
space around the pile shaft shall be filled sufficiently to reestablish lateral support by the soil. Where pile heave occurs, the pile shall be replaced ...
2010 Building Code of NY > 18 Soils and Foundations > 1810 Cast-In-Place Concrete Pile Foundations > 1810.2 Enlarged Base Piles > 1810.2.3 Installation
1810.4.6 Soils and Foundations, Heaved Elements
Deep foundation elements that have heaved during the driving of adjacent elements shall be redriven as necessary to develop the required capacity ...
Building Code 2015 of New York State > 18 Soils and Foundations > 1810 Deep Foundations > 1810.4 Installation > 1810.4.6 Heaved Elements
1810.4.6 Soils and Foundations, Heaved Elements
Deep foundation elements that have heaved during the driving of adjacent elements shall be redriven as necessary to develop the required capacity ...
2020 Building Code of New York State > 18 Soils and Foundations > 1810 Deep Foundations > 1810.4 Installation > 1810.4.6 Heaved Elements
1810.4.1 Soils and Foundations, Structural Integrity
A precast concrete pile shall not be driven before the concrete has attained a compressive strength of at least 75 percent ...
Building Code 2015 of New York State > 18 Soils and Foundations > 1810 Deep Foundations > 1810.4 Installation > 1810.4.1 Structural Integrity