• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

604.2 Heating, Ventilating and Air-Conditioning (HVAC) Systems Equipped With Direct Digital Control (DDC)

Green Construction Code 2015 > 6 Energy Conservation, Efficiency and Co2e Emission Reduction > 604 Automated Demand-Response (Auto-DR) Infrastructure > 604.2 Heating, Ventilating and Air-Conditioning (HVAC) Systems Equipped With Direct Digital Control (DDC)
JUMP TO FULL CODE CHAPTER
HVAC systems with direct digital control (DDC) to the zone level shall be programmed to allow centralized demand shed for noncritical zones in accordance with the following:

  1. The controls shall have a capability to remotely set up the operating cooling temperature setpoints by 4°F (2.2°C) or more in all noncritical zones on signal from a centralized contact or software point within an energy management control system (EMCS).
  2. The controls shall have a capability to remotely set down the operating heating temperature setpoints by 4°F (2.2°C) or more in all noncritical zones on signal from a centralized contact or software point within an EMCS.
  3. The controls shall have capabilities to remotely reset the temperatures in all noncritical zones to original operating levels on signal from a centralized contact or software point within an EMCS.
  4. The controls shall be programmed to provide an adjustable rate of change for the temperature setup and reset.
  5. The controls shall have the following features:
    1. Be accessible to authorized facility operators.
    2. Be equipped with a manual control to allow adjustment of heating and cooling setpoints globally from a single point.
    3. Shall direct the space-conditioning systems to conduct a centralized demand shed, as specified for noncritical zones during the demand-response period, upon receipt of a demand-response signal.

Related Code Sections


604.2 Energy Conservation, Efficiency and Co2e Emission Reduction, Heating, Ventilating and Air-Conditioning (HVAC) Systems Equipped With Direct Digital Control (DDC)
HVAC systems with direct digital control (DDC) to the zone level shall be programmed to allow centralized demand shed for noncritical zones ...
Green Construction Code 2015 > 6 Energy Conservation, Efficiency and Co2e Emission Reduction > 604 Automated Demand-Response (Auto-DR) Infrastructure > 604.2 Heating, Ventilating and Air-Conditioning (HVAC) Systems Equipped With Direct Digital Control (DDC)
C403.6 [CE] Commercial Energy Efficiency, Requirements for Mechanical Systems Serving Multiple Zones
Multiple- zone HVAC systems shall include controls that automatically reset the supply-air temperature in response ...
Energy Conservation Code 2018 > 4 [CE] Commercial Energy Efficiency > C403 Building Mechanical Systems > C403.6 Requirements for Mechanical Systems Serving Multiple Zones
513.4.4 Exhaust Systems, HVAC Systems
The design shall consider the effects of the heating, ventilating and air-conditioning (HVAC) systems on both smoke and fire transport. The analysis ...
Mechanical Code 2015 > 5 Exhaust Systems > 513 Smoke Control Systems > 513.4 Analysis > 513.4.4 HVAC Systems
513.4.4 Exhaust Systems, HVAC Systems
The design shall consider the effects of the heating, ventilating and air-conditioning (HVAC) systems on both smoke and fire transport. The analysis ...
Mechanical Code 2012 > 5 Exhaust Systems > 513 Smoke Control Systems > 513.4 Analysis > 513.4.4 HVAC Systems
513.4.4 Exhaust Systems, HVAC Systems
The design shall consider the effects of the heating, ventilating and air-conditioning (HVAC) systems on both smoke and fire transport. The analysis ...
Mechanical Code 2018 > 5 Exhaust Systems > 513 Smoke Control Systems > 513.4 Analysis > 513.4.4 HVAC Systems
Help Contact Us Privacy Terms
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE