3306.9.8 Hazards to Be Removed
JUMP TO FULL CODE CHAPTER
Prior to the commencement of demolition operations, hazards shall be removed in accordance with Sections 3306.9.8.1 through 3306.9.8.4.
Prior to the commencement of demolition operations, the area authorized to be demolished by the work permit shall be thoroughly cleaned of combustible content and debris, including but not limited to building contents and exterior finishes, down to the structural elements.
Prior to the commencement of demolition operations, all asbestos shall be removed from the area authorized to be demolished by the department work permit, and certification to that effect shall be filed with the department and the Department of Environmental Protection. Such asbestos removal shall be in accordance with Section 28-106 of the Administrative Code and rules promulgated by the commissioner of the Department of Environmental Protection.
Prior to the commencement of demolition operations, all glass located in the area authorized to be demolished by the work permit, including but not limited to glass in windows, doors, skylights, and fixtures, shall be removed.
Exception: Demolition operations relating to the alteration, maintenance, or repair of a façade.
Exception: Demolition operations relating to the alteration, maintenance, or repair of a façade.
Prior to the commencement of demolition operations, all pipes, tanks, boilers, or similar devices containing steam or fuel and located in the area authorized to be demolished by the work permit shall be purged of such steam or fuel.
Exception: Pipes, tanks, boilers, or similar devices containing steam or fuel located in the area authorized to be demolished by the work permit and which will not be disturbed during the course of the demolition operation may, in lieu of being purged, be safeguarded so as to prevent their being damaged during the course of demolition operations.
Exception: Pipes, tanks, boilers, or similar devices containing steam or fuel located in the area authorized to be demolished by the work permit and which will not be disturbed during the course of the demolition operation may, in lieu of being purged, be safeguarded so as to prevent their being damaged during the course of demolition operations.
Related Code Sections
3306.9.8 Safeguards During Construction or Demolition, Hazards to Be Removed
Prior to the commencement of demolition operations, hazards shall be removed in accordance with Sections 3306.9.8.1 through 3306.9.8.4 ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3306 Demolition > 3306.9 Safeguards > 3306.9.8 Hazards to Be Removed
3306.9.8 Safeguards During Construction or Demolition, Hazards to Be Removed
Hazards shall be removed in accordance with the following requirements: Before commencement of actual demolition, all glass in windows, doors ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3306 Demolition > 3306.9 Full Demolition and Partial Demolition Operations > 3306.9.8 Hazards to Be Removed
G102.3.1 Flood-Resistant Construction, Letters of Map Amendment (LOMA)
as being within the area of special flood hazard and shall not approve plans except in compliance with this appendix, unless a letter of map amendment ...
NYC Building Code 2014 > G Flood-Resistant Construction > G102 Applicability > G102.3 Letters of Map Change > G102.3.1 Letters of Map Amendment (LOMA)
G102.3 Flood-Resistant Construction, Letters of Map Change
elevation, the commissioner shall deem such structure or tax lot as being within the area of special flood hazard and shall not approve plans except ...
NYC Building Code 2008 > G Flood-Resistant Construction > G102 Applicability > G102.3 Letters of Map Change
G102.3.1 Flood-Resistant Construction, Letters of Map Amendment (LOMA)
as being within the area of special flood hazard and shall not approve plans except in compliance with this appendix, unless a letter of map amendment ...
NYC Building Code 2008 > G Flood-Resistant Construction > G102 Applicability > G102.3 Letters of Map Change > G102.3.1 Letters of Map Amendment (LOMA)