• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1224.16.3.3 Handwashing Stations

Los Angeles Building Code > 12 Interior Environment > 1224 [OSHPD 1] Hospitals > 1224.16 Anesthesia/Recovery Service Space > 1224.16.3 Recovery and Post-Anesthetia Care Unit (PACU) > 1224.16.3.3 Handwashing Stations
JUMP TO FULL CODE CHAPTER

Handwashing stations shall be provided in the post-anesthesia care unit with at least one for every four patient positions, and for each major fraction thereof, uniformly distributed to provide equal access from each patient station. A handwashing station shall be provided in each single care station room.

Related Code Sections


1224.14.1.6 Interior Environment, Handwashing Stations
A handwashing station shall be provided in the patient room. This handwashing station shall be located at or adjacent to the entrance to the patient ...
Los Angeles Building Code > 12 Interior Environment > 1224 [OSHPD 1] Hospitals > 1224.14 Nursing Service Space > 1224.14.1 Patient Rooms > 1224.14.1.6 Handwashing Stations
1224.39.3.1.2 Interior Environment, Handwashing Stations
A separate dedicated handwashing station with hands-free controls shall be provided in the procedure room ...
Los Angeles Building Code > 12 Interior Environment > 1224 [OSHPD 1] Hospitals > 1224.39 Outpatient Service Space > 1224.39.3 Gastrointestinal Endoscopy > 1224.39.3.1 Procedure Room(s) > 1224.39.3.1.2 Handwashing Stations
1224.39.4.2.4 Interior Environment, Handwashing Stations
Handwashing stations shall be directly accessible to the nurses' station and patient treatment areas. Handwashing stations shall be provided for each ...
Los Angeles Building Code > 12 Interior Environment > 1224 [OSHPD 1] Hospitals > 1224.39 Outpatient Service Space > 1224.39.4 Cancer Treatment/Infusion Therapy Service Space > 1224.39.4.2 Treatment Area > 1224.39.4.2.4 Handwashing Stations
1225.4.2.2.4 Interior Environment, Handwashing Stations
Handwashing stations shall be located in the food preparation area ...
Los Angeles Building Code > 12 Interior Environment > 1225 [OSHPD 2] Skilled Nursing and Intermediate-Care Facilities > 1225.4 Common Elements > 1225.4.2 Dietetic Service Space > 1225.4.2.2 Functional Elements > 1225.4.2.2.4 Handwashing Stations
1226.9.2.1.1 Interior Environment, Handwashing Stations
Handwashing stations shall be directly accessible to the administrative center or nurses' station and to patient treatment areas. Handwashing ...
Los Angeles Building Code > 12 Interior Environment > 1226 [OSHPD 3] Clinics > 1226.9 Chronic Dialysis Clinics > 1226.9.2 Support Areas for Examination and Treatment Rooms > 1226.9.2.1 Administrative Center or Nurse Station > 1226.9.2.1.1 Handwashing Stations
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE