• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R311.8.3 Handrails Required

Residential Code 2018 of Kansas > 3 Building Planning > R311 Means of Egress > R311.8 Ramps > R311.8.3 Handrails Required
JUMP TO FULL CODE CHAPTER
Handrails shall be provided on not less than one side of ramps exceeding a slope of one unit vertical in 12 units horizontal (8.33-percent slope).

R311.8.3.1 Height

Handrail height, measured above the finished surface of the ramp slope, shall be not less than 34 inches (864 mm) and not more than 38 inches (965 mm).

R311.8.3.2 Grip Size

Handrails on ramps shall comply with Section R311.7.8.5.

R311.8.3.3 Continuity

Handrails where required on ramps shall be continuous for the full length of the ramp. Handrail ends shall be returned or shall terminate in newel posts or safety terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches (38 mm) between the wall and the handrails.

Related Code Sections


R311.8.3 Building Planning, Handrails Required
Handrails where required on ramps shall be continuous for the full length of the ramp. Handrail ...
Residential Code 2018 of Kansas > 3 Building Planning > R311 Means of Egress > R311.8 Ramps > R311.8.3 Handrails Required
1011.4.4 Change of Occupancy, Handrails
Existing stairways shall comply with the handrail requirements of Section 805.9 in the area of the change of occupancy classification ...
Existing Building Code 2018 of Kansas > 10 Change of Occupancy > 1011 Change of Occupancy Classification > 1011.4 Means of Egress, General > 1011.4.4 Handrails
1014.1 Means of Egress, Where Required
with Section 1607.8. Handrails required for flights of stairways by Section 1011.11 shall comply with Sections 1014.2 through 1014.9. Handrails ...
Building Code 2018 of Kansas > 10 Means of Egress > 1014 Handrails > 1014.1 Where Required
1014.1 Means of Egress, Where Required
with Section 1607.8 of the International Building Code . Handrails required for flights of stairways by Section 1011.11 shall comply with Sections ...
Fire Code 2018 of Kansas > 10 Means of Egress > 1014 Handrails > 1014.1 Where Required
805.9 Alterations—Level 2, Handrails
The requirements of Sections 805.9.1 and 805.9.2 shall apply to handrails from the work area floor to, and including, the level of exit discharge ...
Existing Building Code 2018 of Kansas > 8 Alterations—Level 2 > 805 Means of Egress > 805.9 Handrails
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING