1607.8.1 Handrails and Guards
JUMP TO FULL CODE CHAPTER
Handrails and guards shall be designed to resist a linear load of 50 pounds per linear foot (plf) (0.73 kN/m) in accordance with Section 4.5.1.1 of ASCE 7. Glass handrail assemblies and guards shall comply with Section 2407.
Exceptions:
- For one- and two-family dwellings, only the single concentrated load required by Section 1607.8.1.1 shall be applied.
- In Group I-3, F, H and S occupancies, for areas that are not accessible to the general public and that have an occupant load less than 50, the minimum load shall be 20 pounds per foot (0.29 kN/m).
Related Code Sections
1607.8.1 Structural Design, Handrails and Guards
Handrails and guards shall be designed to resist a linear load of 50 pounds per linear foot (plf) (0.73 kN/m) in accordance with Section 4.5.1.1 ...
Building Code 2018 of Illinois > 16 Structural Design > 1607 Live Loads > 1607.8 Loads on Handrails, Guards, Grab Bars and Seats > 1607.8.1 Handrails and Guards
1607.9.1 Structural Design, Handrails and Guards
Handrails and guards shall be designed to resist a linear load of 50 pounds per linear foot (plf) (0.73 kN/m) in accordance with Section 4.5.1.1 ...
Building Code 2021 of Illinois > 16 Structural Design > 1607 Live Loads > 1607.9 Loads on Handrails, Guards, Grab Bars and Seats > 1607.9.1 Handrails and Guards
Section 2407 Glass and Glazing, Glass in Handrails and Guards
Glazing materials shall not be installed in handrails or guards in parking garages except for pedestrian areas not exposed to impact from ...
Section 2407 Glass and Glazing, Glass in Handrails and Guards
to be used in handrails and guards where there is no walking surface beneath them or the walking surface is permanently protected from the risk ...
2407.1.1 Glass and Glazing, Loads
The panels and their support system shall be designed to withstand the loads specified in Section 1607.8. Glass guard elements shall be designed using ...
Building Code 2018 of Illinois > 24 Glass and Glazing > 2407 Glass in Handrails and Guards > 2407.1 Materials > 2407.1.1 Loads