// CODE SNIPPET
322.4.3 Handrails and Grab Rails
JUMP TO FULL CODE CHAPTER
Recessed treads shall be provided with a handrail or grab rail on each side of the treads. The clear distance between handrails and grab rails shall be not less than 17 inches (432 mm) and not greater than 24 inches (610 mm).
Related Code Sections
322.4.3 General Compliance, Handrails and Grab Rails
Recessed treads shall be provided with a handrail or grab rail on each side of the treads. The clear distance between handrails and grab rails shall ...
Swimming Pool and Spa Code 2015 of Massachusetts > 3 General Compliance > 322 Ladders and Recessed Treads > 322.4 Recessed Treads > 322.4.3 Handrails and Grab Rails
402.13 Public Swimming Pools, Ladders for Diving Equipment
Ladders shall be provided with two grab rails or two handrails. There shall be a uniform distance between ladder treads, with a 7-inch (178 mm ...
Swimming Pool and Spa Code 2015 of Massachusetts > 4 Public Swimming Pools > 402 Diving > 402.13 Ladders for Diving Equipment
1607.8.1.2 Structural Design, Intermediate Rails
Intermediate rails (all those except the handrail), balusters and panel fillers shall be designed to resist a concentrated load of 50 pounds (0.22 kN ...
MA State Building Code, 9th ed, Base Volume > 16 Structural Design > 1607 Live Loads > 1607.8 Loads on Handrails, Guards, Grab Bars, Seats and Vehicle Barriers > 1607.8.1 Handrails and Guards > 1607.8.1.2 Intermediate Rails
1607.7.1 Structural Design, Handrails and Guards
Handrails and guards shall be designed to resist a load of 50 pounds per linear foot (plf) (0.73 kN/m) applied in any direction at the top ...
MA State Building Code, 8th ed, Base Volume > 16 Structural Design > 1607 Live Loads > 1607.7 Loads on Handrails, Guards, Grab Bars, Seats and Vehicle Barrier Systems > 1607.7.1 Handrails and Guards
1029.15.4 Means of Egress, Rails
Where mid-aisle handrails are provided in stepped aisles , there shall be an additional rail located approximately 12 inches (305 mm) below ...
MA State Building Code, 9th ed, Base Volume > 10 Means of Egress > 1029 Assembly > 1029.15 Handrails > 1029.15.4 Rails