702.6.2 Handrail or Handhold
Go To Full Code Chapter
In-pool stairs shall be equipped with not less than one handrail or handhold that serves all treads with a height of not less than 20 inches (508 mm) above the platform or uppermost tread, whichever is higher.
Related Code Sections
322.3.2 General Compliance, Handrails and Handholds
Ladders shall be provided with two handholds or two handrails. The clear distance between ladder handrails shall be not less than 17 inches (432 mm ...
322.3.2 General Compliance, Handrails and Handholds
Ladders shall be provided with two handholds or two handrails. The clear distance between ladder handrails shall be not less than 17 inches (432 mm ...
702.2.3 Onground Storable Residential Swimming Pools, Handrails or Handholds
A-frame ladders shall have two handrails or handholds that serve all treads. The height of the handrails and handholds shall be not less than 20 ...
702.2.3 Onground Storable Residential Swimming Pools, Handrails or Handholds
A-frame ladders shall have two handrails or handholds that serve all treads. The height of the handrails or handholds shall be not less than 20 ...
702.5.2 Onground Storable Residential Swimming Pools, Handrails or Handholds
In-pool stairs shall be equipped with not less than one handrail or handhold that serves all treads with a height of not less than 20 inches (508 mm ...