1910.120(j) Handling Drums and Containers
JUMP TO FULL CODE CHAPTER
Hazardous substances and contaminated, liquids and other residues shall be handled, transported, labeled, and disposed of in accordance with this paragraph.
When practical, drums and containers shall be inspected and their integrity shall be assured prior to being moved. Drums or containers that cannot be inspected before being moved because of storage conditions (i.e., buried beneath the earth, stacked behind other drums, stacked several tiers high in a pile, etc.) shall be moved to an accessible location and inspected prior to further handling.
Unlabeled drums and containers shall be considered to contain hazardous substances and handled accordingly until the contents are positively identified and labeled.
Drums and containers that cannot be moved without rupture, leakage, or spillage shall be emptied into a sound container using a device classified for the material being transferred.
Site operations shall be organized to minimize the amount of drum or container movement.
Prior to movement of drums or containers, all employees exposed to the transfer operation shall be warned of the potential hazards associated with the contents of the drums or containers.
U.S. Department of Transportation specified salvage drums or containers and suitable quantities of proper absorbent shall be kept available and used in areas where spills, leaks, or ruptures may occur.
Where major spills may occur, a spill containment program, which is part of the employer's safety and health program required in paragraph (b) of this section, shall be implemented to contain and isolate the entire volume of the hazardous substance being transferred.
A ground-penetrating system or other type of detection system or device shall be used to estimate the location and depth of buried drums or containers.
Soil or covering material shall be removed with caution to prevent drum or container rupture.
Fire extinguishing equipment meeting the requirements of 29 CFR Part 1910, Subpart L, shall be on hand and ready for use to control incipient fires.
Drums and containers used during the clean-up shall meet the appropriate DOT, OSHA, and EPA regulations for the wastes that they contain.
The following procedures shall be followed in areas where drums or containers are being opened:
Where an airline respirator system is used, connections to the source of air supply shall be protected from contamination and the entire system shall be protected from physical damage.
If employees must work near or adjacent to drums or containers being opened, a suitable shield that does not interfere with the work operation shall be placed between the employee and the drums or containers being opened to protect the employee in case of accidental explosion.
Controls for drum or container opening equipment, monitoring equipment, and fire suppression equipment shall be located behind the explosion-resistant barrier.
When there is a reasonable possibility of flammable atmospheres being present, material handling equipment and hand tools shall be of the type to prevent sources of ignition.
Drums and containers shall be opened in such a manner that excess interior pressure will be safely relieved. If pressure cannot be relieved from a remote location, appropriate shielding shall be placed between the employee and the drums or containers to reduce the risk of employee injury.
Employees shall not stand upon or work from drums or containers.
Employees not actually involved in opening drums or containers shall be kept a safe distance from the drums or containers being opened.
Material handling equipment used to transfer drums and containers shall be selected, positioned and operated to minimize sources of ignition related to the equipment from igniting vapors released from ruptured drums or containers.
Drums and containers containing radioactive wastes shall not be handled until such time as their hazard to employees is properly assessed.
As a minimum, the following special precautions shall be taken when drums and containers containing or suspected of containing shock-sensitive wastes are handled:
All non-essential employees shall be evacuated from the area of transfer.
An employee alarm system capable of being perceived above surrounding light and noise conditions shall be used to signal the commencement and completion of explosive waste handling activities.
Continuous communications (i.e., portable radios, hand signals, telephones, as appropriate) shall be maintained between the employee-in-charge of the immediate handling area and both the site safety and health supervisor and the command post until such time as the handling operation is completed. Communication equipment or methods that could cause shock sensitive materials to explode shall not be used.
Drums and containers under pressure, as evidenced by bulging or swelling, shall not be moved until such time as the cause for excess pressure is determined and appropriate containment procedures have been implemented to protect employees from explosive relief of the drum.
Drums and containers containing packaged laboratory wastes shall be considered to contain shock-sensitive or explosive materials until they have been characterized.
Caution: Shipping of shock sensitive wastes may be prohibited under U.S. Department of Transportation regulations. Employers and their shippers should refer to 49 CFR 173.21 and 173.50.
Caution: Shipping of shock sensitive wastes may be prohibited under U.S. Department of Transportation regulations. Employers and their shippers should refer to 49 CFR 173.21 and 173.50.
Material handling equipment shall be provided with explosive containment devices or protective shields to protect equipment operators from exploding containers.
In addition to the requirements of paragraph (j)(5) of this section, the following precautions shall be taken, as a minimum, in handling laboratory waste packs (lab packs):
Lab packs shall be opened only when necessary and then only by an individual knowledgeable in the inspection, classification, and segregation of the containers within the pack according to the hazards of the wastes.
If crystalline material is noted on any container, the contents shall be handled as a shock-sensitive waste until the contents are identified.
Sampling of containers and drums shall be done in accordance with a sampling procedure which is part of the site safety and health plan developed for and available to employees and others at the specific worksite.
Drums and containers shall be identified and classified prior to packaging for shipment.
Staging areas shall be provided with adequate access and egress routes.
Bulking of hazardous wastes shall be permitted only after a thorough characterization of the materials has been completed.
Drum or container staging areas shall be kept to the minimum number necessary to safely identify and classify materials and prepare them for transport.
Tanks and vaults containing hazardous substances shall be handled in a manner similar to that for drums and containers, taking into consideration the size of the tank or vault.
Appropriate tank or vault entry procedures as described in the employer's safety and health plan shall be followed whenever employees must enter a tank or vault.
Related Code Sections
1910.120(j) Hazardous Materials, Handling Drums and Containers
Unlabeled drums and containers shall be considered to contain hazardous substances and handled accordingly until the contents are positively ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.120 Hazardous Waste Operations and Emergency Response > 1910.120(j) Handling Drums and Containers
1910.120(j)(4) Hazardous Materials, Radioactive Wastes
Drums and containers containing radioactive wastes shall not be handled until such time as their hazard to employees is properly assessed ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.120 Hazardous Waste Operations and Emergency Response > 1910.120(j) Handling Drums and Containers > 1910.120(j)(4) Radioactive Wastes
1910.120(j)(8) Hazardous Materials, Shipping and Transport
Drums and containers shall be identified and classified prior to packaging for shipment ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.120 Hazardous Waste Operations and Emergency Response > 1910.120(j) Handling Drums and Containers > 1910.120(j)(8) Shipping and Transport
1910.120(j)(6) Hazardous Materials, Laboratory Waste Packs
crystalline material is noted on any container, the contents shall be handled as a shock-sensitive waste until the contents are identified ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.120 Hazardous Waste Operations and Emergency Response > 1910.120(j) Handling Drums and Containers > 1910.120(j)(6) Laboratory Waste Packs
1910.120(j)(9) Hazardous Materials, Tank and Vault Procedures
Tanks and vaults containing hazardous substances shall be handled in a manner similar to that for drums and containers, taking into consideration ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.120 Hazardous Waste Operations and Emergency Response > 1910.120(j) Handling Drums and Containers > 1910.120(j)(9) Tank and Vault Procedures