// CODE SNIPPET
1126A.6 Hand-Activated Door or Gate Hardware
Go To Full Code Chapter
Hand-activated door or gate latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor. Latching and locking doors or gates that are hand-activated and on an accessible route shall be operable with a single effort by lever type hardware, panic bars, push-pull activating bars or other hardware designed to provide passage without requiring the ability to grasp the opening hardware. Locked exit doors or gates shall operate consistent with Section 1126A.4, in the direction of egress. When sliding doors are in the fully open position, operating hardware shall be exposed and usable from both sides.
Exception: Access gates in barrier walls and fences protecting pools, spas and hot tubs shall be permitted to have operable parts of the release of latch on self-latching devices at 54 inches (1372 mm) maximum above the finish floor or ground provided the self-latching devices are not also self-locking devices operated by means of a key, electronic opener or integral combination lock.
1126A.6.1 Lever Type Hardware
The lever or lever of actuated latches or locks shall be curved with a return to within 1/2 inch (12.7 mm) of the door or gate to prevent catching on the clothing of persons during egress.
Related Code Sections
1126A.6 Housing Accessibility, Hand-Activated Door or Gate Hardware
Hand-activated door or gate latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above ...
1126A.6 Housing Accessibility, Hand-Activated Door or Gate Hardware
Hand-activated door or gate latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above ...
1126A.6 Housing Accessibility, Hand-Activated Door or Gate Hardware
Hand-activated
door or gate latching, locking and opening hardware
shall be centered between 30 inches (762 mm) and 44 inches
(1118 mm) above ...
1126A.6.1 Housing Accessibility, Lever Type Hardware
The lever or lever of
actuated latches or locks shall be curved with a return to
within 1/2 inch (12.7 mm) of the door or gate to prevent
catching ...
3119B.2 [DPH] Public Pools, Gates
the pool except where otherwise prohibited by law. Hand activated door or gate opening hardware shall be located at a height no lower than 42 inches (1067 mm ...