2510.5.2.2 Gypsum Sheathing Backing
JUMP TO FULL CODE CHAPTER
Gypsum sheathing is permitted as a backing for metal or wire fabric lath and cement plaster on walls. A water-resistive barrier shall be provided in accordance with Section 2510.6.
Related Code Sections
2510.5.2.2 Gypsum Board, Gypsum Panel Products and Plaster, Gypsum Sheathing Backing
Gypsum sheathing is permitted as a backing for metal or wire fabric lath and cement plaster on walls. A water-resistive barrier shall be provided ...
Building Code 2015 of Pennsylvania > 25 Gypsum Board, Gypsum Panel Products and Plaster > 2510 Lathing and Furring for Cement Plaster (Stucco) > 2510.5 Backing > 2510.5.2 Use of Gypsum Backing Board > 2510.5.2.2 Gypsum Sheathing Backing
2510.5.2.2 Gypsum Board and Plaster, Use of Gypsum Sheathing Backing
Gypsum sheathing is permitted as a backing for metal or wire fabric lath and cement plaster on walls. A water-resistive barrier shall be provided ...
Building Code 2009 of Pennsylvania > 25 Gypsum Board and Plaster > 2510 Lathing and Furring for Cement Plaster (Stucco) > 2510.5 Backing > 2510.5.2 Use of Gypsum Backing Board > 2510.5.2.2 Use of Gypsum Sheathing Backing
2508.4 Gypsum Board, Gypsum Panel Products and Plaster, Joint Treatment
, gypsum backing board or gypsum sheathing.
On multilayer systems where the joints of adjacent layers are offset.
Assemblies tested without ...
Building Code 2015 of Pennsylvania > 25 Gypsum Board, Gypsum Panel Products and Plaster > 2508 Gypsum Construction > 2508.4 Joint Treatment
2508.4 Gypsum Board and Plaster, Joint Treatment
members.
Square edge or tongue-and-groove edge gypsum board (V-edge), gypsum backing board or gypsum sheathing.
On multilayer systems where the joints ...
Building Code 2009 of Pennsylvania > 25 Gypsum Board and Plaster > 2508 Gypsum Construction > 2508.4 Joint Treatment
1505.7 Roof Assemblies and Rooftop Structures, Special Purpose Roofs
addition, an underlayment of 5 / 8 -inch (15.9 mm) Type X water-resistant gypsum backing board or gypsum sheathing shall be placed under minimum nominal 1 ...
Building Code 2009 of Pennsylvania > 15 Roof Assemblies and Rooftop Structures > 1505 Fire Classification > 1505.7 Special Purpose Roofs