Gutters that are used to secure the perimeter edge of the roof membrane on low-slope (less than 2:12 slope) built-up, modified bitumen, and single-ply roofs, shall be designed, constructed and installed to resist wind loads in accordance with Section 1609 and shall be tested in accordance with Test Methods G-1 and G-2 of SPRI GT-1.

Related Code Sections

1504.5 Roof Assemblies and Rooftop Structures, Edge Securement for Low-Slope Roofs
Low-slope built-up, modified bitumen and single-ply roof system metal edge securement, except gutters, shall be designed and installed for wind loads ...
1502.4 Roof Assemblies and Rooftop Structures, Gutters
Gutters and leaders placed on the outside of buildings, other than Group R-3, private garages and buildings of Type V construction, shall ...
1502.4 Roof Assemblies and Rooftop Structures, Gutters
Gutters and leaders placed on the outside of buildings, other than Group R-3, private garages and buildings of Type V construction, shall ...