• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1910.219(o)(3) Guards for Horizontal Overhead Belts

OSHA 1910 General Industry > O Machinery and Machine Guarding > 1910.219 Mechanical Power-Transmission Apparatus > 1910.219(o) Approved Materials > 1910.219(o)(3) Guards for Horizontal Overhead Belts
JUMP TO FULL CODE CHAPTER

1910.219(o)(3)(i)

Guards for horizontal overhead belts shall run the entire length of the belt and follow the line of the pulley to the ceiling or be carried to the nearest wall, thus enclosing the belt effectively. Where belts are so located as to make it impracticable to carry the guard to wall or ceiling, construction of guard shall be such as to enclose completely the top and bottom runs of belt and the face of pulleys.

1910.219(o)(3)(iii)

Suitable reinforcement shall be provided for the ceiling rafters or overhead floor beams, where such is necessary, to sustain safely the weight and stress likely to be imposed by the guard. The interior surface of all guards, by which is meant the surface of the guard with which a belt will come in contact, shall be smooth and free from all projections of any character, except where construction demands it; protruding shallow roundhead rivets may be used. Overhead belt guards shall be at least one-quarter wider than belt which they protect, except that this clearance need not in any case exceed six (6) inches on each side. Overhead rope drive and block and roller-chain-drive guards shall be not less than six (6) inches wider than the drive on each side. In overhead silent chain-drive guards where the chain is held from lateral displacement on the sprockets, the side clearances required on drives of twenty (20) inch centers or under shall be not less than one-fourth inch from the nearest moving chain part, and on drives of over twenty (20) inch centers a minimum of one-half inch from the nearest moving chain part.

1910.219(o)(3)(ii) [Reserved]

Related Code Sections


1910.219(o)(3) Machinery and Machine Guarding, Guards for Horizontal Overhead Belts
Guards for horizontal overhead belts shall run the entire length of the belt and follow the line of the pulley to the ceiling or be carried ...
OSHA 1910 General Industry > O Machinery and Machine Guarding > 1910.219 Mechanical Power-Transmission Apparatus > 1910.219(o) Approved Materials > 1910.219(o)(3) Guards for Horizontal Overhead Belts
1910.219(o) Machinery and Machine Guarding, Approved Materials
The materials and dimensions specified in this paragraph shall apply to all guards, except horizontal overhead belts, rope, cable, or chain guards ...
OSHA 1910 General Industry > O Machinery and Machine Guarding > 1910.219 Mechanical Power-Transmission Apparatus > 1910.219(o) Approved Materials
1910.219(e)(2)(iv) Machinery and Machine Guarding,
Overhead chain and link belt drives are governed by the same rules as overhead horizontal belts and shall be guarded in the same manner as belts ...
OSHA 1910 General Industry > O Machinery and Machine Guarding > 1910.219 Mechanical Power-Transmission Apparatus > 1910.219(e) Belt, Rope, and Chain Drives > 1910.219(e)(2) Overhead Horizontal Belts > 1910.219(e)(2)(iv)
1910.219(e) Machinery and Machine Guarding, Belt, Rope, and Chain Drives
Horizontal overhead belts more than seven (7) feet above floor or platform shall be guarded for their entire length under the following ...
OSHA 1910 General Industry > O Machinery and Machine Guarding > 1910.219 Mechanical Power-Transmission Apparatus > 1910.219(e) Belt, Rope, and Chain Drives
1910.219(e)(4) Machinery and Machine Guarding, Vertical Belts
as horizontal overhead belts, if conditions are as stated in paragraphs (e)(2)(ii) (a) and (c) of this section ...
OSHA 1910 General Industry > O Machinery and Machine Guarding > 1910.219 Mechanical Power-Transmission Apparatus > 1910.219(e) Belt, Rope, and Chain Drives > 1910.219(e)(4) Vertical Belts
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE