1910.219(c)(3) Guarding Vertical and Inclined Shafting
Go To Full Code Chapter
Vertical and inclined shafting seven (7) feet or less from floor or working platform, excepting maintenance runways, shall be enclosed with a stationary casing in accordance with requirements of paragraphs (m) and (o) of this section.
Related Code Sections
1910.219(c)(3) Machinery and Machine Guarding, Guarding Vertical and Inclined Shafting
Vertical and inclined shafting seven (7) feet or less from floor or working platform, excepting maintenance runways, shall be enclosed ...
1910.219(p)(2) Machinery and Machine Guarding, Shafting
Shafting shall be kept in alignment, free from rust and excess oil or grease ...
1910.219(c)(2) Machinery and Machine Guarding, Guarding Horizontal Shafting
All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling ...
1910.266(f)(8) Special Industries, Guarding
Each machine shall be equipped with guarding to protect employees from exposed moving elements, such as but not limited to, shafts, pulleys, belts ...
1910.219(e)(3)(ii) Machinery and Machine Guarding,
All guards for inclined belts shall be arranged in such a manner that a minimum clearance of seven (7) feet is maintained between belt and floor ...