R609.2.2 Grout Spaces
JUMP TO FULL CODE CHAPTER
Fine grout shall be used when interior vertical space to receive grout does not exceed 2 inches (51 mm) in thickness. Interior vertical spaces exceeding 2 inches (51 mm) in thickness shall use coarse or fine grout.
Related Code Sections
R609.2.2 Wall Construction, Grout Spaces
Fine grout shall be used when interior vertical space to receive grout does not exceed 2 inches (51 mm) in thickness. Interior vertical spaces ...
Minnesota Residential Code 2015 > 6 Wall Construction > R609 Grouted Masonry > R609.2 Grouted Multiple-Wythe Masonry > R609.2.2 Grout Spaces
R606.3.5.1 Wall Construction, Grout Placement
plasticity is lost. Grout shall not be pumped through aluminum pipes. Maximum pour heights and the minimum dimensions of spaces provided for grout ...
2020 Minnesota Residential Code > 6 Wall Construction > R606 General Masonry Construction > R606.3 Construction Requirements > R606.3.5 Grouting Requirements > R606.3.5.1 Grout Placement
R609.1 Wall Construction, General
Grouted multiple-wythe masonry is a form of construction in which the space between the wythes is solidly filled with grout. It is not necessary ...
R609.2.3 Wall Construction, Grout Barriers
Vertical grout barriers or dams shall be built of solid masonry across the grout space the entire height of the wall to control the flow ...
Minnesota Residential Code 2015 > 6 Wall Construction > R609 Grouted Masonry > R609.2 Grouted Multiple-Wythe Masonry > R609.2.3 Grout Barriers
R606.3.6.2 Wall Construction, Grout Barriers
Vertical grout barriers or dams shall be built of solid masonry across the grout space the entire height of the wall to control the flow ...
2020 Minnesota Residential Code > 6 Wall Construction > R606 General Masonry Construction > R606.3 Construction Requirements > R606.3.6 Grouted Multiple-Wythe Masonry > R606.3.6.2 Grout Barriers