UpCodes logo
Go To Full Code Chapter
Fine grout shall be used when interior vertical space to receive grout does not exceed 2 inches (51 mm) in thickness. Interior vertical spaces exceeding 2 inches (51 mm) in thickness shall use coarse or fine grout.

Related Code Sections

R609.2.2 Wall Construction, Grout Spaces
Fine grout shall be used when interior vertical space to receive grout does not exceed 2 inches (51 mm) in thickness. Interior vertical spaces ...
R606.3.5.1 Wall Construction, Grout Placement
plasticity is lost. Grout shall not be pumped through aluminum pipes. Maximum pour heights and the minimum dimensions of spaces provided for grout ...
Section R609 Wall Construction, Grouted Masonry
Grouted multiple-wythe masonry is a form of construction in which the space between the wythes is solidly filled with grout. It is not necessary ...
R609.2.3 Wall Construction, Grout Barriers
Vertical grout barriers or dams shall be built of solid masonry across the grout space the entire height of the wall to control the flow of the grout ...
R606.3.6.2 Wall Construction, Grout Barriers
Vertical grout barriers or dams shall be built of solid masonry across the grout space the entire height of the wall to control the flow of the grout ...