• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R606.3.6.2 Grout Barriers

Residential Code 2018 of Kansas > 6 Wall Construction > R606 General Masonry Construction > R606.3 Construction Requirements > R606.3.6 Grouted Multiple-Wythe Masonry > R606.3.6.2 Grout Barriers
JUMP TO FULL CODE CHAPTER
Vertical grout barriers or dams shall be built of solid masonry across the grout space the entire height of the wall to control the flow of the grout horizontally. Grout barriers shall be not more than 25 feet (7620 mm) apart. The grouting of any section of a wall between control barriers shall be completed in one day without interruptions greater than 1 hour.

Related Code Sections


R606.3.6.2 Wall Construction, Grout Barriers
Vertical grout barriers or dams shall be built of solid masonry across the grout space the entire height of the wall to control the flow ...
Residential Code 2018 of Kansas > 6 Wall Construction > R606 General Masonry Construction > R606.3 Construction Requirements > R606.3.6 Grouted Multiple-Wythe Masonry > R606.3.6.2 Grout Barriers
R703.8.4.2 Wall Covering, Grout Fill
As an alternative to the airspace required by Table R703.8.4, grout shall be permitted to fill the airspace. Where the airspace is filled with grout ...
Residential Code 2018 of Kansas > 7 Wall Covering > R703 Exterior Covering > R703.8 Anchored Stone and Masonry Veneer, General > R703.8.4 Anchorage > R703.8.4.2 Grout Fill
8.3.4.2.5.1 Features of Fire Protection,
designed as a fire barrier Where concrete, grout, or mortar has been used to fill the annular spaces around cast-iron, copper, or steel piping, conduit ...
Life Safety Code 2018 of Kansas > 8 Features of Fire Protection > 8.3 Fire Barriers > 8.3.4 Penetrations > 8.3.4.2* Firestop Systems and Devices Required > 8.3.4.2.5 Alternative Firestop Requirements > 8.3.4.2.5.1
2103.3 Masonry, Grout
Grout shall comply with Article 2.2 of TMS 602 ...
Building Code 2018 of Kansas > 21 Masonry > 2103 Masonry Construction Materials > 2103.3 Grout
R606.3.5 Wall Construction, Grouting Requirements
Grout shall be a plastic mix suitable for pumping without segregation of the constituents and shall be mixed thoroughly. Grout shall be placed ...
Residential Code 2018 of Kansas > 6 Wall Construction > R606 General Masonry Construction > R606.3 Construction Requirements > R606.3.5 Grouting Requirements
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING