• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

[F] 907.2.11.2 Groups R-2, R-2.1 , R-3, R-3.1 and R-4 and I-4

Los Angeles Building Code > 9 Fire Protection Systems > 907 Fire Alarm and Detection Systems > 907.2 Where Required—New Buildings and Structures > 907.2.11 Single- And Multiple-Station Smoke Alarms > 907.2.11.2 Groups R-2, R-2.1 , R-3, R-3.1 and R-4 and I-4
JUMP TO FULL CODE CHAPTER

Single- or multiple-station smoke alarms shall be installed and maintained in Groups R-2, R-2.1, R-3, R-3.1 and R-4 regardless of occupant load at all of the following locations:

  1. On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms.
  2. In each room used for sleeping purposes.
  3. In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level.
  4. In a Group R-3.1 occupancies, in addition to the above, smoke alarms shall be provided throughout the habitable areas of the dwelling unit except kitchens.

See Section 907.2.11.8 for specific location requirements.

907.2.11.2.1 Group I-4 Occupancies

Large family day-care homes shall be equipped with State Fire Marshal approved and listed single station residential type smoke alarms.

907.2.11.2.2 Group R-3.1

In all facilities housing a bedridden client, smoke alarms shall receive their primary power from the building wiring when such wiring is served from a commercial source and shall be equipped with a battery backup. Smoke alarms shall be electrically interconnected so as to cause all smoke alarms to sound a distinctive alarm signal upon actuation of any single smoke alarm. Such alarm signal shall be audible throughout the facility at a minimal level of 15 dB above ambient noise level. These devices need not be interconnected to any other fire alarm device, have a control unit, or be electrically supervised or provided with emergency power.

907.2.11.2.3 Smoke Alarms

Smoke alarms shall be tested and maintained in accordance with the manufacturer's instructions. Smoke alarms that no longer function shall be replaced.

Related Code Sections


907.2.11.2 Fire Protection Systems, Groups R-2, R-2.1 , R-3, R-3.1 and R-4 and I-4
Single- or multiple-station smoke alarms shall be installed and maintained in Groups R-2, R-2.1 , R-3, R-3.1 and R-4 regardless of occupant load ...
Los Angeles Building Code > 9 Fire Protection Systems > 907 Fire Alarm and Detection Systems > 907.2 Where Required—New Buildings and Structures > 907.2.11 Single- And Multiple-Station Smoke Alarms > 907.2.11.2 Groups R-2, R-2.1 , R-3, R-3.1 and R-4 and I-4
Section 508 General Building Heights and Areas, Mixed Use and Occupancy
all other occupancies in accordance with Section 508.4. Group I-1, R-1, R-2, R-2.1 and R-3 dwelling units and sleeping units shall be separated from ...
Los Angeles Building Code > 5 General Building Heights and Areas > 508 Mixed Use and Occupancy
1020.1 Means of Egress, Construction
30 Not Permitted 1 A e , B, F, M, S, U Greater than 30 1 0 R-1, R-2, R-3, R-3.1, R-4 Greater than 10 1 d 1 I-2 a , I-2.1 , I ...
Los Angeles Building Code > 10 Means of Egress > 1020 Corridors > 1020.1 Construction
Section 302 Use and Occupancy Classification, Classification
): Groups R-1, R-2, R-2.1, R-3, R-3.1 and R-4. Storage (see Section 311): Groups S-1 and S-2 Utility and Miscellaneous (see Section 312): Group U ...
Los Angeles Building Code > 3 Use and Occupancy Classification > 302 Classification
1006.2.1 Means of Egress, Egress Based on Occupant Load and Common Path of Egress Travel Distance
NP NP 25 b H-4, H-5 10 NP NP 75 b I-2 d , I-2.1 , I-4 10 NP NP 75 a I-3 10 NP NP 100 a R-1 10 NP NP 75 ...
Los Angeles Building Code > 10 Means of Egress > 1006 Number of Exits and Exit Access Doorways > 1006.2 Egress From Spaces > 1006.2.1 Egress Based on Occupant Load and Common Path of Egress Travel Distance
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE