907.2.10.2 Groups R-2, R-2.1, R-2.2 , R-3, R-3.1, and R-4
JUMP TO FULL CODE CHAPTER
Single or multiple-station smoke alarms shall be installed and maintained in Groups R-2, R-2.1, R-2.2, R-3, R-3.1 and R-4 regardless of occupant load at all of the following locations:
- On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms.
- In each room used for sleeping purposes.
- In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level.
- In a Group R-3.1 occupancies, in addition to the above, smoke alarms shall be provided throughout the habitable areas of the dwelling unit except kitchens.
See Section 907.2.10.8 for specific location requirements.
Licensed Group R-2.1 occupancies housing more than six nonambulatory, elderly clients shall be provided with an approved manual and automatic fire alarm system.
Exceptions: Buildings housing nonambulatory clients on the first story only and which are protected throughout by the following:
- An approved and supervised automatic sprinkler system, as specified in Sections 903.3.1.1 or 903.3.1.2, which upon activation will initiate the fire alarm system to notify all occupants.
- A manual fire alarm system.
- Smoke alarms required by Section 907.2.11.
Single- and multiple-station smoke alarms shall be installed in accordance with Section 907.2.10.
Large family day-care homes shall be equipped with State Fire Marshal approved and listed single station residential type smoke alarms.
In all facilities housing a bedridden client, smoke alarms shall receive their primary power from the building wiring when such wiring is served from a commercial source and shall be equipped with a battery backup. Smoke alarms shall be electrically interconnected so as to cause all smoke alarms to sound a distinctive alarm signal upon actuation of any single smoke alarm. Such alarm signal shall be audible throughout the facility at a minimal level of 15 db above ambient noise level. These devices need not be interconnected to any other fire alarm device, have a control panel, or be electronically supervised or provided with emergency power.
Smoke alarms shall be tested and maintained in accordance with the manufacturer's instructions. Smoke alarms that no longer function shall be replaced.
See the California Residential Code for existing Group R-3 occupancies or Chapter 11 of the California Fire Code for all other existing Group R occupancies.
Related Code Sections
907.2.10.2 Fire Protection and Life Safety Systems, Groups R-2, R-2.1, R-2.2 , R-3, R-3.1, and R-4
Single or multiple-station smoke alarms shall be installed and maintained in Groups R-2, R-2.1, R-2.2 , R-3, R-3.1 and R-4 regardless of occupant ...
California Fire Code 2019 > 9 Fire Protection and Life Safety Systems > 907 Fire Alarm and Detection Systems > 907.2 Where Required—New Buildings and Structures > 907.2.10 Single- And Multiple-Station Smoke Alarms > 907.2.10.2 Groups R-2, R-2.1, R-2.2 , R-3, R-3.1, and R-4
907.2.10.2.1.1 Fire Protection and Life Safety Systems, Smoke Alarms
Single- and multiple-station smoke alarms shall be installed in accordance with Section 907.2.10 ...
California Fire Code 2019 > 9 Fire Protection and Life Safety Systems > 907 Fire Alarm and Detection Systems > 907.2 Where Required—New Buildings and Structures > 907.2.10 Single- And Multiple-Station Smoke Alarms > 907.2.10.2 Groups R-2, R-2.1, R-2.2 , R-3, R-3.1, and R-4 > 907.2.10.2.1 Licensed Group R-2.1 Occupancies > 907.2.10.2.1.1 Smoke Alarms
1019.3 Means of Egress, Occupancies Other Than Groups I-2, I-2.1, I-3, and R-2.1
not be open to other stories. In Group R-1, R-2, R-2.1, R-2.2, R-3 or R-3.1 occupancies, exit access stairways and ramps connecting four stories ...
California Fire Code 2019 > 10 Means of Egress > 1019 Exit Access Stairways and Ramps > 1019.3 Occupancies Other Than Groups I-2, I-2.1, I-3, and R-2.1
Section 1019 Means of Egress, Exit Access Stairways and Ramps
In Group R-1, R-2, R-2.1, R-2.2, R-3 or R-3.1 occupancies, exit access stairways and ramps connecting four stories or less serving and contained ...
907.2.10 Fire Protection and Life Safety Systems, Single- And Multiple-Station Smoke Alarms
shall be installed and maintained in Groups R-2, R-2.1, R-2.2 , R-3, R-3.1 and R-4 regardless of occupant load at all of the following locations ...
California Fire Code 2019 > 9 Fire Protection and Life Safety Systems > 907 Fire Alarm and Detection Systems > 907.2 Where Required—New Buildings and Structures > 907.2.10 Single- And Multiple-Station Smoke Alarms