• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

907.2.11.2 Groups R-2 (Except "SRO" Occupancies as Defined in Section 310.2), R-3, R-4 and I-1

Ohio Building Code 2011 > 9 Fire Protection Systems > 907 Fire Alarm and Detection Systems > 907.2 Where Required—New Buildings and Structures > 907.2.11 Single- And Multiple-Station Smoke Alarms > 907.2.11.2 Groups R-2 (Except "SRO" Occupancies as Defined in Section 310.2), R-3, R-4 and I-1
JUMP TO FULL CODE CHAPTER
Single-or multiple-station smoke alarms shall be installed and maintained in Groups R-2 (except "SRO" occupancies as defined in Section 310.2), R-3, R-4 and I-1 regardless of occupant load at all of the following locations:
  1. On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms.
  2. In each room used for sleeping purposes.
    Exception: Single- or multiple-station smoke alarms in Group I-1 occupanices shall not be required where smoke detectors are provided in the sleeping rooms as part of an automatic smoke detection system.
  3. In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level.

Related Code Sections


907.2.11.2 Fire Protection Systems, Groups R-2 (Except "SRO" Occupancies as Defined in Section 310.2), R-3, R-4 and I-1
Single-or multiple-station smoke alarms shall be installed and maintained in Groups R-2 (except "SRO" occupancies as defined in Section 310.2), R-3 ...
Ohio Building Code 2011 > 9 Fire Protection Systems > 907 Fire Alarm and Detection Systems > 907.2 Where Required—New Buildings and Structures > 907.2.11 Single- And Multiple-Station Smoke Alarms > 907.2.11.2 Groups R-2 (Except "SRO" Occupancies as Defined in Section 310.2), R-3, R-4 and I-1
310.2 Use and Occupancy Classification, Definitions
See Section 202. DORMITORY. A space in a building where group sleeping accommodations are provided in one room, or in a series of closely ...
Ohio Building Code 2011 > 3 Use and Occupancy Classification > 310 Residential Group R > 310.2 Definitions
903.2.8 Fire Protection Systems, Group R
in buildings of Group R-3 and R-4. An automatic sprinkler system is not required in buildings of Group R-2 permitted to have a single exit per Section ...
Ohio Building Code 2011 > 9 Fire Protection Systems > 903 Automatic Sprinkler Systems > 903.2 Where Required > 903.2.8 Group R
Section 118 Ohio Administrative Code 1301:7-7-01 Administration, Hotel and SRO Facility License
certificate of occupancy demonstrating a use group classification for the SRO facility of R-2 as approved and issued by the building official having ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-01 Administration > 118 Hotel and SRO Facility License
907.2.11.1 Fire Protection Systems, Group R-1 and "SRO"occupancies (As Defined in Section 310.2)
Single-or multiple-station smoke alarms shall be installed in all of the following locations in Group R-1 and "SRO" occupancies: In sleeping ...
Ohio Building Code 2011 > 9 Fire Protection Systems > 907 Fire Alarm and Detection Systems > 907.2 Where Required—New Buildings and Structures > 907.2.11 Single- And Multiple-Station Smoke Alarms > 907.2.11.1 Group R-1 and "SRO"occupancies (As Defined in Section 310.2)
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE