Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

803.2.2 Groups A, B, E, F-1, H, I, M, R-1, R-2, R-4, S-1 and S-2

Existing Building Code 2018 of Illinois > 8 Alterations—Level 2 > 803 Fire Protection > 803.2 Automatic Sprinkler Systems > 803.2.2 Groups A, B, E, F-1, H, I, M, R-1, R-2, R-4, S-1 and S-2
JUMP TO FULL CODE CHAPTER

In buildings with occupancies in Groups A, B, E, F-1, H, I, M, R-1, R-2, R-4, S-1 and S-2, work areas that have exits or corridors shared by more than one tenant or that have exits or corridors serving an occupant load greater than 30 shall be provided with automatic sprinkler protection where both of the following conditions occur:

  1. The work area is required to be provided with automatic sprinkler protection in accordance with the International Building Code as applicable to new construction.
  2. The work area exceeds 50 percent of the floor area.

Exception: If the building does not have sufficient municipal water supply for design of a fire sprinkler system available to the floor without installation of a new fire pump, work areas shall be protected by an automatic smoke detection system throughout all occupiable spaces other than sleeping units or individual dwelling units that activates the occupant notification system in accordance with Sections 907.4, 907.5 and 907.6 of the International Building Code.

803.2.2.1 Mixed Uses

In work areas containing mixed uses, one or more of which requires automatic sprinkler protection in accordance with Section 803.2.2, such protection shall not be required throughout the work area provided that the uses requiring such protection are separated from those not requiring protection by fire-resistance-rated construction having a minimum 2-hour rating for Group H and a minimum 1-hour rating for all other occupancy groups.

Related Code Sections


803.2.2.1 Alterations—Level 2, Mixed Uses
by fire-resistance-rated construction having a minimum 2-hour rating for Group H and a minimum 1-hour rating for all other occupancy groups ...
Existing Building Code 2018 of Illinois > 8 Alterations—Level 2 > 803 Fire Protection > 803.2 Automatic Sprinkler Systems > 803.2.2 Groups A, B, E, F-1, H, I, M, R-1, R-2, R-4, S-1 and S-2 > 803.2.2.1 Mixed Uses
706.4 Fire and Smoke Protection Features, Fire-Resistance Rating
RATINGS GROUP FIRE-RESISTANCE RATING (hours) A, B, E, H-4, I, R-1, R-2, U 3 a F-1, H-3 b , H-5, M, S-1 3 H-1, H-2 4 ...
Building Code 2018 of Illinois > 7 Fire and Smoke Protection Features > 706 Fire Walls > 706.4 Fire-Resistance Rating
302.1 Occupancy Classification and Use, Occupancy Classification
-3 and I-4. Mercantile (see Section 309): Group M. Residential (see Section 310): Groups R-1, R-2, R-3 and R-4. Storage (see Section 311): Groups S ...
Building Code 2018 of Illinois > 3 Occupancy Classification and Use > 302 Occupancy Classification and Use Designation > 302.1 Occupancy Classification
1006.3.3 Means of Egress, Single Exits
plane A, B b , E F b , M, U 49 75 H-2, H-3 3 25 H-4, H-5, I, R-1, R-2 a, c 10 75 S b, d 29 75 Second ...
Building Code 2018 of Illinois > 10 Means of Egress > 1006 Number of Exits and Exit Access Doorways > 1006.3 Egress From Stories or Occupied Roofs > 1006.3.3 Single Exits
Section 508 General Building Heights and Areas, Mixed Use and Occupancy
-2 R a F-2, S-2 b , U B e , F-1, M, S-1 H-1 H-2 H-3, H-4 H-5 S NS S NS S NS S NS S NS S ...
Building Code 2018 of Illinois > 5 General Building Heights and Areas > 508 Mixed Use and Occupancy
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE