• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

[F] 905.5.1 Groups A-1 and A-2

Los Angeles Building Code > 9 Fire Protection Systems > 905 Standpipe Systems > 905.5 Location of Class II Standpipe Hose Connections > 905.5.1 Groups A-1 and A-2
JUMP TO FULL CODE CHAPTER
In Group A-1 and A-2 occupancies having occupant loads exceeding 1,000 persons, hose connections shall be located on each side of any stage, on each side of the rear of the auditorium, on each side of the balcony and on each tier of dressing rooms.

Related Code Sections


905.5.1 Fire Protection Systems, Groups A-1 and A-2
In Group A-1 and A-2 occupancies having occupant loads exceeding 1,000 persons, hose connections shall be located on each side of any stage, on each ...
Los Angeles Building Code > 9 Fire Protection Systems > 905 Standpipe Systems > 905.5 Location of Class II Standpipe Hose Connections > 905.5.1 Groups A-1 and A-2
905.5.1 Fire Protection Systems, Groups A-1 and A-2
In Group A-1 and A-2 occupancies with occupant loads of more than 1,000, hose connections shall be located on each side of any stage, on each side ...
2017 LA City Fire Code > 9 Fire Protection Systems > 905 Standpipe Systems > 905.5 Location of Class II Standpipe Hose Connections > 905.5.1 Groups A-1 and A-2
905.5.1 Fire Protection and Life Safety Systems, Groups A-1 and A-2
In Group A-1 and A-2 occupancies having occupant loads exceeding 1,000 persons, hose connections shall be located on each side of any stage ...
Los Angeles Building Code > 9 Fire Protection and Life Safety Systems > 905 Standpipe Systems > 905.5 Location of Class II Standpipe Hose Connections > 905.5.1 Groups A-1 and A-2
507.4.1 General Building Heights and Areas, Mixed Occupancy Buildings With Groups A-1 and A-2
Group A-1 and A-2 occupancies of other than Type V construction shall be permitted within mixed occupancy buildings of unlimited area complying ...
Los Angeles Building Code > 5 General Building Heights and Areas > 507 Unlimited Area Buildings > 507.4 Sprinklered, One-Story Buildings > 507.4.1 Mixed Occupancy Buildings With Groups A-1 and A-2
507.4.1 General Building Heights and Areas, Mixed Occupancy Buildings With Groups A-1 and A-2
Group A-1 and A-2 occupancies of other than Type V construction shall be permitted within mixed occupancy buildings of unlimited area complying ...
Los Angeles Building Code > 5 General Building Heights and Areas > 507 Unlimited Area Buildings > 507.4 Sprinklered, One-Story Buildings > 507.4.1 Mixed Occupancy Buildings With Groups A-1 and A-2
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE