• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

E3701.5.2 Grouping

2015 Michigan Residential Code > 37 Branch Circuit and Feeder Requirements > E3701 General > E3701.5 Multiwire Branch Circuits > E3701.5.2 Grouping
JUMP TO FULL CODE CHAPTER
The ungrounded and grounded circuit conductors of each multiwire branch circuit shall be grouped by cable ties or similar means in at least one location within the panelboard or other point of origination. [210.4(D)]

Exception: Grouping shall not be required where the circuit conductors enter from a cable or raceway unique to the circuit, thereby making the grouping obvious, or where the conductors are identified at their terminations with numbered wire markers corresponding to their appropriate circuit number. [210.4(D) Exception].

Related Code Sections


E3701.5.2 Branch Circuit and Feeder Requirements, Grouping
The ungrounded and grounded circuit conductors of each multiwire branch circuit shall be grouped by cable ties or similar means in at least one ...
2015 Michigan Residential Code > 37 Branch Circuit and Feeder Requirements > E3701 General > E3701.5 Multiwire Branch Circuits > E3701.5.2 Grouping
1016.2.2 Means of Egress, Group E
Egress from classrooms in group E occupancies shall be limited to pass through 1 intervening space before reaching an exit access door leading ...
2015 Michigan Building Code > 10 Means of Egress > 1016 Exit Access > 1016.2 Egress Through Intervening Spaces > 1016.2.2 Group E
1107.5 Accessibility, Group I
Accessible units and Type B units shall be provided in Group I occupancies in accordance with Sections 1107.5.1 through 1107.5.5 ...
2015 Michigan Building Code > 11 Accessibility > 1107 Dwelling Units and Sleeping Units > 1107.5 Group I
1810.2.5 Soils and Foundations, Group Effects
The analysis shall include group effects on lateral behavior where the center-to-center spacing of deep foundation elements in the direction ...
2015 Michigan Building Code > 18 Soils and Foundations > 1810 Deep Foundations > 1810.2 Analysis > 1810.2.5 Group Effects
412.6.1 Special Detailed Requirements Based on Use and Occupancy, Occupancy Group
Aircraft paint hangars shall be classified as Group H-2. Aircraft paint hangars shall comply with the applicable requirements of this code ...
2015 Michigan Building Code > 4 Special Detailed Requirements Based on Use and Occupancy > 412 Aircraft-Related Occupancies > 412.6 Aircraft Paint Hangars > 412.6.1 Occupancy Group
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE