• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

903.2.10 Group S-2

NYC Building Code 2014 > 9 Fire Protection Systems > 903 Automatic Sprinkler Systems > 903.2 Where Required > 903.2.10 Group S-2
JUMP TO FULL CODE CHAPTER
An automatic sprinkler system shall be installed throughout buildings greater than 5,000 square feet (465 m2) in area where the main use or dominant occupancy is Group S-2.

903.2.10.1 Commercial Parking Garages

An automatic sprinkler system shall be provided throughout buildings used for storage of commercial trucks or buses where the fire area exceeds 5,000 square feet (465 m2).

903.2.10.2 Group S-2 Fire Areas

An automatic sprinkler system shall be provided throughout any Group S-2 occupancy fire area greater than 5,000 square feet (465 m2).

903.2.10.3 Parking Garages

An automatic sprinkler system shall be provided throughout buildings classified as enclosed parking garages in accordance with Section 406.4 or where an open or enclosed parking garage is located beneath other occupancy groups.
Exception: Parking garages located beneath Group R-3 occupancies.

Related Code Sections


903.2.10 Fire Protection Systems, Group S-2
or dominant occupancy is Group S-2. An automatic sprinkler ...
NYC Building Code 2014 > 9 Fire Protection Systems > 903 Automatic Sprinkler Systems > 903.2 Where Required > 903.2.10 Group S-2
903.2.9 Fire Protection Systems, Group S-2
or dominant occupancy is Group S-2. An automatic sprinkler ...
NYC Building Code 2008 > 9 Fire Protection Systems > 903 Automatic Sprinkler Systems > 903.2 Where Required > 903.2.9 Group S-2
507.14 General Building Heights and Areas; Separation of Occupancies, Group S-2 Buildings
Nothwithstanding the provisions of Sections 507.2 and 507.3, the area of a Group S-2 building of Type IB, IIA, IIIA or IV construction shall ...
NYC Building Code 2008 > 5 General Building Heights and Areas; Separation of Occupancies > 507 Unlimited Area Buildings > 507.14 Group S-2 Buildings
507.17 General Building Heights and Areas; Separation of Occupancies, Group S-2 Buildings
Notwithstanding the provisions of Sections 507.2 and 507.3, the area of a Group S-2 building of Type IB, IIA, IIIA or IV construction shall ...
NYC Building Code 2014 > 5 General Building Heights and Areas; Separation of Occupancies > 507 Unlimited Area Buildings > 507.17 Group S-2 Buildings
510.3 General Building Heights and Areas; Separation of Occupancies, Group S-2 Enclosed Parking Garage With Group S-2 Open Parking Garage Above
A Group S-2 enclosed parking garage with no more than one story above grade plane and located below a Group S-2 open parking garage shall ...
NYC Building Code 2014 > 5 General Building Heights and Areas; Separation of Occupancies > 510 Special Provisions > 510.3 Group S-2 Enclosed Parking Garage With Group S-2 Open Parking Garage Above
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE