510.6 Group R-2 Buildings of Type IIA Construction
JUMP TO FULL CODE CHAPTER
The height limitation for buildings of Type IIA construction in Group R-2 shall be increased to nine stories and 100 feet (30 480 mm) where the building is separated by not less than 50 feet (15 240 mm) from any other building on the lot and from lot lines, the exits are segregated in an area enclosed by a 2-hour fire-resistance-rated fire wall and the first-floor assembly has a fire-resistance rating of not less than 11/2 hours.
Related Code Sections
509.6 General Building Heights and Areas; Separation of Occupancies, Group R-2 Buildings of Type IIA Construction
The height limitation for buildings of Type IIA construction in Group R-2 shall be increased to nine stories and 100 feet (30 480 mm) where ...
NYC Building Code 2008 > 5 General Building Heights and Areas; Separation of Occupancies > 509 Special Provisions > 509.6 Group R-2 Buildings of Type IIA Construction
510.6 General Building Heights and Areas; Separation of Occupancies, Group R-2 Buildings of Type IIA Construction
The height limitation for buildings of Type IIA construction in Group R-2 shall be increased to nine stories and 100 feet (30 480 mm) where ...
NYC Building Code 2014 > 5 General Building Heights and Areas; Separation of Occupancies > 510 Special Provisions > 510.6 Group R-2 Buildings of Type IIA Construction
507.13 General Building Heights and Areas; Separation of Occupancies, Group R Buildings
The area of a Group R-1 and R-2 building of Type IIA, IIIA or IV construction shall not be limited where the building is protected throughout ...
NYC Building Code 2008 > 5 General Building Heights and Areas; Separation of Occupancies > 507 Unlimited Area Buildings > 507.13 Group R Buildings
507.16 General Building Heights and Areas; Separation of Occupancies, Group R Buildings
The area of Group R-1 and R-2 buildings of Type IIA, IIIA or IV construction shall not be limited where the building is protected throughout ...
NYC Building Code 2014 > 5 General Building Heights and Areas; Separation of Occupancies > 507 Unlimited Area Buildings > 507.16 Group R Buildings
507.14 General Building Heights and Areas; Separation of Occupancies, Group F-2 Buildings
Notwithstanding the provisions of Sections 507.2 and 507.3, the area of a Group F-2 building of Type IIA, IIIA or IV construction shall ...
NYC Building Code 2014 > 5 General Building Heights and Areas; Separation of Occupancies > 507 Unlimited Area Buildings > 507.14 Group F-2 Buildings