1107.6.2 Group R-2

Building Code 2015 of Utah > 11 Accessibility > 1107 Dwelling Units and Sleeping Units > 1107.6 Group R > 1107.6.2 Group R-2
JUMP TO FULL CODE CHAPTER
Accessible units, Type A units and Type B units shall be provided in Group R-2 occupancies in accordance with Sections 1107.6.2.1 through 1107.6.2.3.

1107.6.2.1 Live/Work Units

In live/work units constructed in accordance with Section 419, the nonresidential portion is required to be accessible. In a structure where there are four or more live/work units intended to be occupied as a residence, the residential portion of the live/work unit shall be a Type B unit.

Exception: The number of Type B units is permitted to be reduced in accordance with Section 1107.7.

1107.6.2.2 Apartment Houses, Monasteries and Convents

Type A units and Type B units shall be provided in apartment houses, monasteries and convents in accordance with Sections 1107.6.2.2.1 and 1107.6.2.2.2.

1107.6.2.2.1 Type A Units

In Group R-2 occupancies containing more than 20 dwelling units or sleeping units, at least 2 percent but not less than one of the units shall be a Type A unit. All Group R-2 units on a site shall be considered to determine the total number of units and the required number of Type A units. Type A units shall be dispersed among the various classes of units. Bedrooms in monasteries and convents shall be counted as sleeping units for the purpose of determining the number of units. Where the sleeping units are grouped into suites, only one sleeping unit in each suite shall count towards the number of required Type A units.

Exceptions:

1. The number of Type A units is permitted to be reduced in accordance with Section 1107.7.

2. Existing structures on a site shall not contribute to the total number of units on a site.

1107.6.2.2.2 Type B Units

Where there are four or more dwelling units or sleeping units intended to be occupied as a residence in a single structure, every dwelling unit and sleeping unit intended to be occupied as a residence shall be a Type B unit.

Exception: The number of Type B units is permitted to be reduced in accordance with Section 1107.7.

1107.6.2.3 Group R-2 Other Than Live/Work Units, Apartment Houses, Monasteries and Convents

In Group R-2 occupancies, other than live/work units, apartment houses, monasteries and convents falling within the scope of Sections 1107.6.2.1 and 1107.6.2.2, Accessible units and Type B units shall be provided in accordance with Sections 1107.6.2.3.1 and 1107.6.2.3.2. Bedrooms within congregate living facilities shall be counted as sleeping units for the purpose of determining the number of units. Where the sleeping units are grouped into suites, only one sleeping unit in each suite shall be permitted to count towards the number of required Accessible units.

1107.6.2.3.1 Accessible Units

Accessible dwelling units and sleeping units shall be provided in accordance with Table 1107.6.1.1.

1107.6.2.3.2 Type B Units

Where there are four or more dwelling units or sleeping units intended to be occupied as a residence in a single structure, every dwelling unit and every sleeping unit intended to be occupied as a residence shall be a Type B unit.

Exception: The number of Type B units is permitted to be reduced in accordance with Section 1107.7.
Share URL

Copy and paste the link below into emails, chats or browsers.

Copy

You can also copy or bookmark the link from your browser's address bar.

Related Code Sections


1107.6.2 Accessibility, Group R-2
Accessible units, Type A units and Type B units shall be provided in Group R-2 occupancies in accordance with Sections 1107.6.2.1 through ...
Building Code 2018 of Utah > 11 Accessibility > 1107 Dwelling Units and Sleeping Units > 1107.6 Group R > 1107.6.2 Group R-2
1107.6.2 Accessibility, Group R-2
Accessible units , Type A units and Type B units shall be provided in Group R-2 occupancies in accordance with Sections 1107.6.2.1 through ...
Building Code 2015 of Utah > 11 Accessibility > 1107 Dwelling Units and Sleeping Units > 1107.6 Group R > 1107.6.2 Group R-2
803.4.1.6 Alterations—level 2, Group R-2
A fire alarm system shall be installed in work areas of Group R-2 apartment buildings as required by the International Fire Code for existing ...
Existing Building Code 2018 of Utah > 8 Alterations—level 2 > 803 Fire Protection > 803.4 Fire alarm and detection > 803.4.1 Occupancy requirements > 803.4.1.6 Group R-2
804.4.1.6 Alterations - Level 2, Group R-2
A fire alarm system shall be installed in work areas of Group R-2 apartment buildings as required by the International Fire Code for existing ...
Existing Building Code 2015 of Utah > 8 Alterations - Level 2 > 804 Fire Protection > 804.4 Fire Alarm and Detection > 804.4.1 Occupancy Requirements > 804.4.1.6 Group R-2
907.2.9 Fire Protection Systems, Group R-2
Fire alarm systems and smoke alarms shall be installed in Group R-2 occupancies as required in Sections 907.2.9.1 through 907.2.9.3 ...
Building Code 2015 of Utah > 9 Fire Protection Systems > 907 Fire Alarm and Detection Systems > 907.2 Where Required‒new Buildings and Structures > 907.2.9 Group R-2
About UpCodes

UpCodes provides an intuitive resource to navigate building regulations.

Codes are organized by jurisdiction to help you understand which regulations apply to your project.


Find Your Codes
COMPANY INFO About Free Law Contact Careers Terms Privacy Press Kit
CATEGORY General New York City New York State California Codes Building Codes Online
PREMIUM Features Pricing Sign Up Log In
CODES IBC 2015 IRC 2015 IPC 2015 California Building Code 2016 Popular Sections

FOLLOW US