Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

709.5.1 Group I-2 and Ambulatory Care Facilities

2018 North Carolina Building Code > 7 Fire and Smoke Protection Features > 709 Smoke Barriers > 709.5 Openings > 709.5.1 Group I-2 and Ambulatory Care Facilities
JUMP TO FULL CODE CHAPTER
In Group I-2 and ambulatory care facilities, where doors are installed across a corridor, the doors shall be automatic-closing by smoke detection in accordance with Section 716.5.9.3 and shall have a vision panel with fire-protection-rated glazing materials in fire-protection-rated frames, the area of which shall not exceed that tested.

Related Code Sections


709.5.1 Fire and Smoke Protection Features, Group I-2 and Ambulatory Care Facilities
In Group I-2 and ambulatory care facilities , where doors are installed across a corridor, the doors shall be automatic-closing by smoke detection ...
2018 North Carolina Building Code > 7 Fire and Smoke Protection Features > 709 Smoke Barriers > 709.5 Openings > 709.5.1 Group I-2 and Ambulatory Care Facilities
909.5.3.1 Fire Protection Systems, Group I-1 Condition 2; Group I-2 and Ambulatory Care Facilities
In Group I-1 Condition 2, Group I-2 and ambulatory care facilities , where doors are installed across a corridor , the doors shall be automatic ...
2018 North Carolina Building Code > 9 Fire Protection Systems > 909 Smoke Control Systems > 909.5 Smoke Barrier Construction > 909.5.3 Opening Protection > 909.5.3.1 Group I-1 Condition 2; Group I-2 and Ambulatory Care Facilities
513.5.3.1 Exhaust Systems, Group I-1 Condition 2; Group I-2 and Ambulatory Care Facilities
In Group I-1 Condition 2; Group I-2 and ambulatory care facilities , where doors are installed across a corridor , the doors shall be automatic ...
2018 North Carolina Mechanical Code > 5 Exhaust Systems > 513 Smoke Control Systems > 513.5 Smoke Barrier Construction > 513.5.3 Opening Protection > 513.5.3.1 Group I-1 Condition 2; Group I-2 and Ambulatory Care Facilities
909.5.3.1 Fire Protection Systems, Group I-1 Condition 2, Group I-2 and Ambulatory Care Facilities
In Group I-1 Condition 2, Group I-2 and ambulatory care facilities , where doors are installed across a corridor , the doors shall be automatic ...
2018 North Carolina Fire Prevention Code > 9 Fire Protection Systems > 909 Smoke Control Systems > 909.5 Smoke Barrier Construction > 909.5.3 Opening Protection > 909.5.3.1 Group I-1 Condition 2, Group I-2 and Ambulatory Care Facilities
909.5 Fire Protection Systems, Smoke Barrier Construction
between smoke zones that are protected utilizing the airflow method. In Group I-1 Condition 2, Group I-2 and ambulatory care facilities, where a pair ...
2018 North Carolina Building Code > 9 Fire Protection Systems > 909 Smoke Control Systems > 909.5 Smoke Barrier Construction
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE