• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

907.2.4 Group F, General

Minnesota Fire Code 2015 > 9 Fire Protection Systems > 907 Fire Alarm and Detection Systems > 907.2 Where Required in New Buildings and Occupancies > 907.2.4 Group F, General
JUMP TO FULL CODE CHAPTER
A fire alarm system shall be installed in accordance with Sections 907.2.4 through 907.2.4.2 in Group F occupancies that are two or more stories in height and have an occupant load of 500 or more above or below the lowest level of exit discharge.
Exception: A fire alarm system is not required when an approved automatic fire-extinguishing system is installed throughout the building.

907.2.4.1 Initiation

Initiation of the fire alarm system shall be by manual and automatic means. Approved automatic fire detectors shall be provided in boiler and furnace rooms, trash-collection rooms, kitchens, mechanical and electrical rooms, and similar areas.

907.2.4.2 Notification

Activation of the fire alarm system shall initiate a general evacuation signal.

Related Code Sections


907.2.4 Fire Protection Systems, Group F, General
A fire alarm system shall be installed in accordance with Sections 907.2.4 through 907.2.4.2 in Group F occupancies that are two or more stories ...
Minnesota Fire Code 2015 > 9 Fire Protection Systems > 907 Fire Alarm and Detection Systems > 907.2 Where Required in New Buildings and Occupancies > 907.2.4 Group F, General
907.2.4 Fire Protection Systems, Group F, General
A fire alarm system shall be installed in accordance with Sections 907.2.4.through 907.2.4.2.in Group F occupancies that are two or more stories ...
Minnesota Building Code 2015 > 9 Fire Protection Systems > 907 Fire Alarm and Detection Systems > 907.2 Where Required—New Buildings and Structures > 907.2.4 Group F, General
903.2.4 Fire Protection and Life Safety Systems, Group F-1
An automatic sprinkler system shall be provided throughout all buildings containing a Group F-1 occupancy where one of the following conditions ...
2020 Minnesota Building Code > 9 Fire Protection and Life Safety Systems > 903 Automatic Sprinkler Systems > 903.2 Where Required > 903.2.4 Group F-1
903.2.4 Fire Protection and Life Safety Systems, Group F-1
An automatic sprinkler system shall be provided throughout all buildings containing a Group F-1 occupancy where one of the following conditions ...
2020 Minnesota State Fire Code > 9 Fire Protection and Life Safety Systems > 903 Automatic Sprinkler Systems > 903.2 Where Required > 903.2.4 Group F-1
903.2.4 Fire Protection Systems, Group F-1
An automatic sprinkler system shall be provided throughout all buildings containing a Group F-1 occupancy where one of the following conditions ...
Minnesota Fire Code 2015 > 9 Fire Protection Systems > 903 Automatic Sprinkler Systems > 903.2 Where Required > 903.2.4 Group F-1
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE