• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

3314.11.5.4 Grounding Conductor

NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3314 Scaffolds > 3314.11 Suspension Rope > 3314.11.5 Suspended Scaffold Welding Precautions for Arcing Prevention > 3314.11.5.4 Grounding Conductor
JUMP TO FULL CODE CHAPTER
In addition to a work lead attachment required by the welding process, a grounding conductor shall be connected from the scaffold to the structure. The size of the connector shall be at least the size of the welding process work lead, and this conductor shall not be in series with the welding process or the work piece.

Related Code Sections


3314.11.5.4 Safeguards During Construction or Demolition, Grounding Conductor
In addition to a work lead attachment required by the welding process, a grounding conductor shall be connected from the scaffold to the structure ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3314 Scaffolds > 3314.11 Suspension Rope > 3314.11.5 Arcing Prevention > 3314.11.5.4 Grounding Conductor
3314.11.5.4 Safeguards During Construction or Demolition, Grounding Conductor
In addition to a work lead attachment required by the welding process, a grounding conductor shall be connected from the scaffold to the structure ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3314 Scaffolds > 3314.11 Suspension Rope > 3314.11.5 Suspended Scaffold Welding Precautions for Arcing Prevention > 3314.11.5.4 Grounding Conductor
Section 310 General Regulations, Electrical Bonding
Each above-ground portion of a gas piping system that is likely to become energized shall be continuously bonded electrically to an effective ground ...
NYC Fuel Gas Code 2014 > 3 General Regulations > 310 Electrical Bonding
Section 310 General Regulations, Electrical Bonding
to the equipment grounding conductor of the circuit supplying that equipment ...
NYC Fuel Gas Code 2008 > 3 General Regulations > 310 Electrical Bonding
1006.8 Boilers, Water Heaters and Pressure Vessels, Electrical Requirements
The power supply to the electrical control system shall be from a two-wire branch circuit that has a grounded conductor, or from an isolation ...
NYC Mechanical Code 2008 > 10 Boilers, Water Heaters and Pressure Vessels > 1006 Safety and Pressure Relief Valves and Controls > 1006.8 Electrical Requirements
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE