Section H109 Ground Signs
JUMP TO FULL CODE CHAPTER
Ground signs erected inside the fire districts shall be constructed entirely of noncombustible materials and the facings of such signs shall be of noncombustible materials, except as permitted by Section H107. Outside the fire districts, the structure of ground signs exceeding 25 feet (7620 mm) in height above grade or exceeding 2500 square feet (232 m2) in display area shall be constructed of noncombustible materials, and the facing of such signs shall be noncombustible, except as permitted by Section H107.
The bottom coping of every ground sign shall be not less than 3 feet (914 mm) above the ground or street level, which space can be filled with platform decorative trim or light wooden construction.
Where wood anchors or supports are embedded in the soil, the wood shall be pressure treated with an approved preservative.
Related Code Sections
Section H109 Outdoor Signs, Ground Signs
Ground signs erected inside the fire districts shall be constructed entirely of noncombustible materials and the facings of such signs shall ...
Section H109 Outdoor Signs, Ground Signs
Ground signs erected inside the fire districts shall be constructed entirely of noncombustible materials and the facings of such signs shall ...
§27-500 Special Uses and Occupancies, Ground Signs
(a) Location. No part of a ground sign shall be erected so as to project beyond the street line, except as specifically permitted by the provisions ...
NYC 1968 Code (Vol I) > 7 Special Uses and Occupancies > 17 Outdoor Signs and Display Structures > §27-500 Ground Signs
H109.3 Outdoor Signs, Wood Anchors and Supports
Where wood anchors or supports are embedded in the soil, the wood shall be pressure treated with an approved preservative ...
H107.1.3.1 Outdoor Signs, Plastic Area Limitations on Noncombustible Ground Signs and Wall Signs
On ground signs and wall signs required to be constructed of noncombustible materials, if the display surface does not exceed 150 square feet (13.9 m ...
NYC Building Code 2014 > H Outdoor Signs > H107 Material Limitations > H107.1 Use of Combustibles > H107.1.3 Plastic Area Limitations for All Other Signs > H107.1.3.1 Plastic Area Limitations on Noncombustible Ground Signs and Wall Signs