• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

32-433 Ground Floor Use in C1, C2 and C4 Districts in the Borough of Staten Island

NYC Zoning Resolution > III Commercial District Regulations > 2 - Use Regulations > 32-40 Supplementary Use Regulations > 32-43 Ground Floor Use in Certain Locations > 32-433 Ground Floor Use in C1, C2 and C4 Districts in the Borough of Staten Island
JUMP TO FULL CODE CHAPTER

C1 C2 C4

In all C1, C2 and C4 Districts in the Borough of Staten Island, ground floor uses shall conform with the provisions of this Section.

(a)        Ground floor level use requirements

(1)        Along primary street frontages

For buildings, or portions thereof, with primary street frontage, as defined in Section 37-311, uses on the ground floor level, to the minimum depth set forth in Section 37-32 (Ground Floor Depth Requirements for Certain Uses), shall be limited to non-residential uses except for Type 1 lobbies, and entrances and exits to accessory parking spaces provided in accordance with the applicable provisions of Section 37-33 (Maximum Width of Certain Uses). Any accessory off-street parking spaces located on the ground floor level shall be wrapped by floor area in accordance with the provisions of paragraph (a) of Section 37-35 (Parking Wrap and Screening Requirements).

(2)        Along secondary street frontages

For buildings, or portions thereof, with secondary street frontage, as defined in Section 37-311, all uses permitted by the underlying district shall be permitted on the ground floor level, provided that any accessory off-street parking spaces located on the ground floor level shall be wrapped or screened in accordance with the provisions of Section 37-35.

The level of the finished floor of such ground floor shall be located not higher than two feet above nor lower than two feet below the as-built level of the adjoining street.

(b)        Non-conforming buildings

Buildings containing non-conforming residential uses on the ground floor shall be permitted to enlarge without regard to the use regulations of this Section, provided that such enlargement complies with the provisions of the residential yard regulations set forth in Section 23-40.

Related Code Sections


Article 3 Building Limitations, Fire Districts
of Bronx. (c) All of the borough of Brooklyn. (d) Such portions of the boroughs of Staten Island and Queens as are indicated on the "fire district maps ...
NYC 1968 Code (Vol I) > 4 Building Limitations > 3 Fire Districts
D101.2 Fire Districts, Establishment of Fire District
All of the borough of Brooklyn. Such portions of the boroughs of Staten Island and Queens as are indicated on the "fire district maps" as per ...
NYC Building Code 2008 > D Fire Districts > D101 General > D101.2 Establishment of Fire District
D101.2 Fire Districts, Establishment of Fire District
All of the borough of Brooklyn. Such portions of the boroughs of Staten Island and Queens as are indicated on the "fire district maps" as per ...
NYC Building Code 2014 > D Fire Districts > D101 General > D101.2 Establishment of Fire District
3304.3.3 Safeguards During Construction or Demolition, Notification to the Department of Environmental Protection
of 135 th Street in the borough of Manhattan, or greater than 100 feet (30 480 mm) in the borough of Brooklyn, Queens, or Staten Island or south ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3304 Soil and Foundation Work > 3304.3 Notification > 3304.3.3 Notification to the Department of Environmental Protection
D106.1 Fire Districts, Fire District Maps
Within the boroughs of Richmond and Queens, the fire districts shall comprise such areas indicated on the "fire district maps" as per Figures D106.1 ...
NYC Building Code 2014 > D Fire Districts > D106 Fire District Maps for the Boroughs of Richmond and Queens > D106.1 Fire District Maps
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE